14 Resetting the number of connected lifting modules
The automatic detection of the lifting modules is activated by default.
A reduced number is detected as dangerous fault. A higher number
is accepted.
If one lifting module fails, the control is blocked. Error code "F16" is indicated in
the display of the hand switch.
Check the connections of all lifting modules.
Replace the defective lifting module.
If the control is to be operated in a new confi guration, proceed as follows:
Button / display
or
P14
Button [1]
P60
Button [1]
or
Button [1]
15 Distribution, basic
15.1 Reset – distribution "basic" restart
Button / display
or
P17
Button [1]
P90
Button [1]
Button [2]
15.2 Resetting the "basic" distribution
Reset if the distribution no longer functions properly. During reset and
restart, the system is also checked for newly connected or removed
control units.
Resetting the number of connected lifting modules
Instructions
Push shortly four times in a row
A tone sequence resounds and "PXX" is shown in the display (A)
Push to select a menu item
Select menu item
Push to select menu item
The display shows "P60"
Push to select menu item
The display indicates the number of lifting modules stored by the
control unit.
Push to change the number of lifting modules.
Push to save the entry
Instructions
Call menu
Push to select a menu item
Distribution menu
Push to confi rm menu item
Distribution menu restart / reset
Push to confi rm menu item
Push to exit the menu (without changes)
3 842 564 712/2022-06, MPS: Steuergerät, Bosch Rexroth AG