2. Attach the gun to the other end of the high pressure hose.
Tighten securely with two adjustable wrenches.
3. Plug the sprayer into a properly grounded outlet or heavy
duty grounded extension cord. Do not use more than 100
feet of cord. If you must spray a long distance from a
power source, use more paint hose, not more extension
cords. Use a minimum size of 16 gauge for power
extension cords up to 50 feet in length, or 12 to 14 gauge
for power extension cords between 50 and 100 feet in
length.
PRESSURE RELIEF
PROCEDURE
Follow this procedure after the unit is assembled and before
any operation which involves the spray gun such as cleaning
and maintenance or changing tips or accessories.
1. Turn the pressure control knob counterclockwise to its
lowest setting.
2. Turn the PRIME/SPRAY knob to PRIME (
PRIME/SPRAY
Knob
Pressure
Control Knob
3. Trigger the gun to remove any pressure which may still be
in the hose.
4. Lock the gun by turning the gun safety switch so that it is
parallel to the gun body.
Locked
WARNING
Injection hazard. Do not spray without the tip guard in place.
NEVER trigger the gun unless the tip is completely turned to
either the spray or the unclog position. ALWAYS engage the gun
safety switch before removing, replacing or cleaning tip.
R
English
PRIMING
Preparing to Prime
1. Fill the inlet valve with water or with a light household oil.
2. Make certain that the PRIME/SPRAY knob is set to
PRIME (
counterclockwise to the lowest pressure setting.
3. Turn the motor switch to ON.
4. Increase the pressure by turning the pressure control
knob clockwise 1/2 turn.
5. Force the inlet valve to open and close by pushing on it
with a screwdriver or the eraser end of a pencil. It should
move up and down about 1/16 of an inch. Continue until
water or oil is sucked into the sprayer. This will wet the
).
moving parts and break loose any old paint residue.
6. Put the palm of your hand over the inlet. Turn the
pressure control knob clockwise to its maximum setting.
You should feel suction coming from the inlet valve. If you
do not, see the section on cleaning and servicing the outlet
valve.
7. Turn the pressure control knob counterclockwise to the
minimum pressure setting.
6
) and that the pressure control knob is turned
© 1996 Wagner Spray Tech - All rights reserved.