Water Supply Requirements
Read all directions before you begin.
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
TOOLS NEEDED: Flat-blade screwdriver, ⁷⁄₁₆" and ¹⁄₂" open-end
wrenches or 2 adjustable wrenches, ¹⁄₄" nut driver and drill bit,
cordless drill.
IMPORTANT:
If you turn the refrigerator on before the water line is
connected, turn the ice maker OFF.
All installations must meet local plumbing code
requirements.
Use copper tubing and check for leaks. Install copper tubing
only in areas where the household temperatures will remain
above freezing.
NOTE: Your refrigerator dealer has a kit available with a ¹⁄₄"
(6.35 mm) saddle-type shutoff valve, a union, and copper
tubing. Before purchasing, make sure a saddle-type valve
complies with your local plumbing codes. Do not use a piercing-
type or ³⁄₁₆" (4.76 mm) saddle valve which reduces water flow
and clogs more easily.
Water Pressure
IMPORTANT: A cold water supply with water pressure between
30 and 120 psi (207 and 827 kPa) is required to operate the ice
maker.
NOTE: If the water pressure is less than what is required, ice
cubes could be hollow or irregular shaped.
If you have questions about your water pressure, call a licensed,
qualified plumber.
Reverse Osmosis Water Supply
If a reverse osmosis water filtration system is connected to your
cold water supply, the water pressure to the reverse osmosis
system needs to be a minimum of 40 to 60 psi (276 to 414 kPa).
If the ice maker is still not operating properly:
Check to see whether the sediment filter in the reverse
osmosis system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill
after heavy usage.
All manuals and user guides at all-guides.com
Read all directions before you begin.
IMPORTANT: If you turn the refrigerator on before the water
line is connected, turn the ice maker OFF.
1. Unplug refrigerator or disconnect power.
2. Turn OFF main water supply. Turn ON nearest faucet long
3. Locate a ½" to 1¹⁄₄" (1.25 cm to 3.18 cm) vertical cold water
4. Determine the length of copper tubing you need. Measure
5. Using a cordless drill, drill a ¹⁄₄" hole in the cold water pipe
6. Fasten the shutoff valve to the cold water pipe with the pipe
7. Slip the compression sleeve and compression nut on the
8. Place the free end of the tubing in a container or sink, and
Connect the Water Supply
Connect to Water Line
enough to clear line of water.
pipe near the refrigerator.
IMPORTANT:
Make sure it is a cold water pipe.
Horizontal pipe will work, but drill on the top side of the
pipe, not the bottom. This will help keep water away
from the drill and normal sediment from collecting in the
valve.
from the connection on the lower left rear of refrigerator to
the water pipe. Add 7 ft (2.1 m) to allow for cleaning. Use
¹⁄₄" (6.35 mm) O.D. (outside diameter) copper tubing. Be
sure both ends of copper tubing are cut square.
you have selected.
G
F
E
A. Cold water pipe
B. Pipe clamp
C. Copper tubing
D. Compression nut
clamp. Be sure the outlet end is solidly in the ¹⁄₄" drilled hole
in the water pipe and that the washer is under the pipe
clamp. Tighten the packing nut. Tighten the pipe clamp
screws slowly and evenly so washer makes a watertight seal.
Do not overtighten or you may crush the copper tubing.
copper tubing as shown. Insert the end of the tubing into the
outlet end squarely as far as it will go. Screw compression
nut onto outlet end with adjustable wrench. Do not
overtighten.
turn ON the main water supply. Flush the tubing until water
is clear. Turn OFF the shutoff valve on the water pipe. Coil
the copper tubing.
A
B
C
D
E. Compression sleeve
F. Shutoff valve
G. Packing nut
7