Daewoo GD Serie Manual De Usuario página 7

Ocultar thumbs Ver también para GD Serie:
Idiomas disponibles

Idiomas disponibles

EN
4) Choke
4. Choke
The choke is used Io provide an enriched fuel mixture when starting a cold engine. It can be opened
and closed by operating the chock lever or choke rod manually. Move the lever or the rod to the
CLOSE position to enrich the mixture.
5) Circuit Breaker
The circuit breaker will automatically switch OFF If there is a short circuit or a significant overload of
the generator at the receptacle. If the circuit breaker is switched OFF automatically, check that the
appliance is working properly and does not exceed the rated load capacity of the circuit before
switching the circuit breaker ON again, The circuit breaker may be used to switch the generator
power ON or OFF.
6) Ground Terminal
The generator ground terminal Is. connected to the panel of the generator, the metal
non-current carrying parts of the generator, and the ground terminals of each
receptacle. Before using the ground terminal, consult a qualified electrician, electrical
inspector or local agency having jurisdiction for local codes or ordinances that apply to the intended
use of the generator.
7) Oil Alert System
The oil alert system is designed to prevent engine damage caused by an insufficient
amount of oil in the crankcase. Before the oil level in the crankcase can fall below a
safe limit the oil alert system will automatically shut down the engine (the engine
switch will remain in the ON position). The oil alert system shuts down the engine and
the engine will not start. If this occurs, first check engine oil.
6
loading