Ensure  that  the  flow  rate  of  the  well  is  higher  than 
that  required,  in  order  to  prevent  the  pump  to  start  and 
stop with a frequency greater than the permitted limit. 
 
Respect maximum depth of immersion as specified in 
the pump's data plate. 
 
After  installing  the  electric  pump  in  a  well,  be  sure 
to close off the opening properly and complete safety. 
 
It is advisable to use pipes with an internal diameter 
at least equal to that of the delivery pipe, so as to avoid a 
fall in the performance of the pump and the possibility of 
clogging. 
 
Install  a  check  valve  on  the  outlet  of  the  pump  to 
prevent  the  line  from  emptying  every  time  the  pump 
stops. 
 
 The  hydraulic  connection  of  the  pump  can  be 
carried out with iron or rigid plastic parts. If a plastic hose 
is chosen instead of a metallic line, make sure that it can 
sustain  the  pressure  provided  by  the  pump.  Prevent  the 
hose  from  becoming  twisted  because,  in  addition  to 
preventing  the  desired  flow,  proper  pump  operation  will 
be hindered. 
 When using in a well, it is recommended to secure 
 
the power cable to the delivery pipe with hose clamps or 
insulating tape every 50cm/1mt 
 
 Seal  any  piping  connections:  air  infiltration  in  the 
suction pipe negatively affects pump operation. 
 
 
7
STARTUP 
 
Startup 
 
After  making  all  the  connections  as  specified  in  the 
inverter  manual,  turn  on  the  power.  At  the  first  start  the 
parameters  relating  to  the  pressure  required  and  the 
pump  absorption  must  be  set.  For  more  information  on 
this procedure, please refer to the inverter manual. 
 
After  starting  the  pump,  wait  up  to  30  seconds 
before the priming of the pump. 
In  case  of  operating  faults,  see  chapter  12  "Faults, 
causes and solutions" and the section alarms and faults of 
the inverter manual. 
 
 
8
MAINTENANCE AND CLEANING 
SKILLED  PERSONNEL:  The  Electropump  can  only  be 
 
disassembled  by  competent  skilled  personnel,  in 
possession  of  the  qualifications  required  by  the 
legislation  in  force.  In  any  case,  all  repair  and 
 
maintenance  jobs  must  be  carried  out  only  after  having 
disconnected the pump from yhe power mains. 
 
Maintenance 
 
In  normal  operation  the  pump  does  not  require  any 
type  of  maintenance,  thanks  to  the  mechanical  seal 
lubrificated  in  an  oil  bath  and  to  the  greased‐for.life 
bearings. 
During  dismantling  it  is  necessary  to  pay  great 
 
attention to sharp parts which may cause injures. 
When  the  pump  remains  inactive  for  a  long  time  at 
 
temperatures lower than 0°C, it is necessary to ensure that 
there  is  no  water  residue  which  might  freeze,  causing 
cracking  of  the  pump  component.  This  operation  is  also 
raccomended  in case  of  prolonged  inactivity  of the  pump 
at normal temperature. 
 
If the pump has been used with substances that tend 
to deposit, rinse it after use with a powerful jet of water so 
as to avoid the formation of deposits or scale which would, 
tend to reduce the pump characteristics. 
Cleaning
Periodically clean the inside of all the filters present in 
suction and delivery system. Removing any particles that 
may have sucked in. 
 
9
REPAIRS AND SPARE PARTS 
Skilled Personnel 
If  the  pump  should  malfunction,  contact  only 
authorized  and  specialized  repair  shops  for  any  repair 
work.  The  manufacturer's  permission  must  be  obtained 
prior to opening or modifying the pump. Please note that 
we cannot assume any responsibility for demages to our 
electric  pump  if  it  has  been  opened  and  reassembled 
without  our  persmission  or  the  permission  of  an 
authorized repair shop. 
If the supply cable is damaged, it must be replaced 
by  the  manufacturer  or  its  service  agent  or  a  similarly 
qualified persons in order to prevent all risks. 
Spare parts
All  the  spare  parts  used  in  repairs  must  be  original 
ones.  On  request  the  manufacturer  provides  the  spare 
parts list. 
The  main  most  common  special  maintenance 
operations are generally as follows:  
 Replacement of the seal; 
 Replacement of the sealing ring; 
 Replacement of the bearings. 
 