UV LAMPS
UVC ACTIVE
SETTING UP AND COMMISSIONING
Attention! Dangerous electrical voltage.
For fault-free operation, set up the device only in the permitted positions. Consider
the required distances. Use mounting material suitable underground. The
attachment must carry the device safely. Pay attention to weight. Insert a gate
valve or ball valve into the water inlet or in front of the device if placed below the
water level. During maintenance the water supply can be blocked.
KEEP DISTANCES:
The safety distance of the device to the water must be at least 2 meters. Allow
sufficient space for maintenance. Provide at least twice the housing length to
remove the lamp and quartz tube.
TURN ON:
The device is switched off on delivery. After installation, switch on the pump.
Check all connections for leaks. Connect the device to the main power. The device
switches on automatically. The control window shows whether the UVC lamp is blue.
REGULAR MAINTENANCE:
The device must be regularly checked and cleaned to ensure proper function.
TURN OFF:
Remove the main plug.
Type
pH-Value
Free Chlorine
Bound Chlorine
Chlorine Content
Salinity – < 3,5 %
Water Temperature
Fresh water or salt water can affect the appearance of the device. These impairments
are excluded from the warranty.
PRECAUTIONS:
Before you reach into the water, remove the main plug from the power supply
before working on the device.
The unit will turn on automatically when the power connection is established.
Note: First switch on the pump, then the UVC clarifier.
10
Possible consequences: Death or serious injury.
Fresh Water
7,2 ... 7,6
0,3 ... 0,6 mg / l
< 0,2 mg / l
< 200 mg / l
+4 °C ... +30 °C
Salt Water
7,5 ... 8,5
< 0,3 mg / l
+4 °C ... +25 °C