valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated
and, if possible, cooled before recovery occurs. The recovery equipment shall be in good working
order with a set of instructions concerning the equipment that is at hand and shall be suitable for the
recovery of flammable refrigerants. In addition, a set of calibrated weighing scales shall be available
and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good
condition. Before using the recovery machine, check that it is in satisfactory working order, has been
properly maintained and that any associated electrical components are sealed to prevent ignition in
the event of a refrigerant release. Consult manufacturer if in doubt. The recovered refrigerant shall be
returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer
Note arranged. Do not mix refrigerants in recovery units and especially not in cylinders. If compressors
or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level
to make certain that flammable refrigerant does not remain within the lubricant.
The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only
electric heating to the compressor body shall be employed to accelerate this process.
When oil is drained from a system, it shall be carried out safely.
1 - DESCRIPTION OF THE APPLIANCE
1.1 - FEATURES
The appliance is packaged singularly in a cardboard packaging.
Store the packaging in vertical position.
The dehumidifier powerfully removes moisture from the air to decrease the humidity level of the room
and keep the indoor air dry and comfortable.
It is possible to select the desired level of humidity by means of the digital humidistat.
Thanks to the timer, it is possible to set the automatic switching on and off of the appliance.
1.2 - IDENTIFICATION OF THE MAIN COMPONENTS
1.
Front shell
2.
Air outlet grid
2a. Flap
3.
Handle
4.
Control panel
4a. Upper display
4b. Front display
5.
Air inlet grid
6.
Back shell
7.
Water tank
2 - INSTALLATION
2.1 - APPLIANCE TRANSPORT
• Transport and handling of the appliance must be carried out in vertical position.
• If it is transported in a horizontal position, wait at least one hour before starting it.
• Before moving or transporting the appliance, completely drain condensation by
working as described in paragraph 3.4.a
CAUTION
Transporting the appliance on delicate floors (for instance: wooden floors):
• Completely drain condensation.
• Pay particular attention while moving the appliance since the wheels may mark the
floor. Although the wheels are made from a rigid material and are swivelling, they
could get damaged by use or excessive dirt.
It is recommended to check that the wheels are clean and that they can move
freely.
EN - 10
(Fig.A)
8.
Wheels
9.
Supply cord
10. Filter
10a. Active carbons filter
10b. HEPA filter
11. Data plate
12. Instruction booklet
13. Condensation drain connection
14. Hose for continuous condensation drain