5.2 Programmes for timed drying
Dryness Level
Extra Dry
For towelling materi‐
als
Cupboard Dry
For items to be stor‐
ed
Cupboard Dry
For items to be stor‐
ed
Iron Dry
Suitable for ironing
1) Hints for test institute. The test performance, in accordance with EN 50229:2015, must
be carried out with a FIRST drying load of the maximum declared drying capacity by setting
210 minutes by means of the Tiempo de secado button for the Secado Algodón pro‐
gramme. The SECOND drying load with the residual load must be tested by setting 130 mi‐
nutes by means of the Tiempo de secado button for the Secado Algodón programme.
6. CONSUMPTION VALUES
Stated values are obtained in laboratory conditions with relevant stand‐
ards. Different causes can change the data: the quantity and type of
laundry and ambient temperature. Water pressure, the supply voltage
and the temperature of inlet water may also affect the washing pro‐
gramme duration.
Technical specifications may be changed without prior notice to improve
the quality of product.
Programmes
Cottons 60°C
Type of fabric
Cottons and Linen
(bathrobes, bath towels,
etc)
Cottons and Linen
1)
(bathrobes, bath towels,
etc)
Synthetics and mixed
fabrics
(jumpers, blouses, under‐
wear, household and bed
linen)
Cottons and Linen
(sheets, tablecloths, shirts,
etc)
Load
(kg)
7
Load
(kg)
4
3
1.5
4
3
1.5
2
1
4
3
1.5
Energy
Water con‐
con‐
sumption
sumption
(litre)
(kWh)
1.35
67
ENGLISH
Spin
Suggested
speed
duration
(rpm)
(mins)
1200
215 - 220
1200
160 - 180
1200
95 - 105
1200
205 - 210
1200
150 - 170
1200
85 - 95
900
90 - 100
900
55 - 65
1200
140 - 150
1200
90 - 100
1200
60 - 70
Approximate pro‐
gramme duration
(minutes)
150
13