How To Program The Paging Function; How To Program The Self Activation Function - Comelit HFX-700B Manual Tecnico

Ocultar thumbs Ver también para HFX-700B:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

5
When programming is complete,
„ Set S2 DIP switches 1-2-3-4 to the combination 1111 (PROG setting). In this DIP switch
setting, the keys control the programmed functions; the NON-programmed keys control
functions referred to on line 0000, see
„ Restore the user code setting on S1.

4.2.3.3 HOW TO PROGRAM THE PAGING FUNCTION

Example:
key = general paging to user code 3
Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
„ Set S2 DIP switch 5-6 to the combination 01
» the Privacy LED flashes
2
1. Choose the function: refer to the
combination in which the paging function (PAG) is listed for the keys you wish to program.
2. Addressing:
„ for internal paging set S1 DIP switches with the same user code of the internal unit.
„ for general paging to another user code set S1 DIP switches with the desired address in
accordance with
3
Select the key to be associated with the function
„ Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
4
Exit programming mode
„ To exit programming mode, set S2 DIP switches 5-6 to the combination 00
» the Privacy LED switches off
5
When programming is complete,
„ Set S2 DIP switches 1-2-3-4 to the combination 1111 (PROG setting). In this DIP switch
setting, the keys control the programmed functions; the NON-programmed keys control
functions referred to on line 0000, see
„ Restore the user code setting on S1.

4.2.3.4 HOW TO PROGRAM THE SELF ACTIVATION FUNCTION

Example:
key
Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
„ Set S2 DIP switch 5-6 to the combination 01
» the Privacy LED flashes
2
1. Choose the function: refer to
combination in which the self activation function (AI) is listed for the keys you wish to program.
2. Addressing:
„ for self activation function don't set S1 DIP switches
3
Select the key to be associated with the function
„ Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
4
Exit programming mode
„ To exit programming mode, set S2 DIP switches 5-6 to the combination 00
» the Privacy LED switches off
5
When programming is complete,
„ Set S2 DIP switches 1-2-3-4 to the combination 1111 (PROG setting). In this DIP switch
setting, the keys control the programmed functions; the NON-programmed keys control
functions referred to on line 0000, see
„ Restore the user code setting on S1.
22
"Preset function
"Preset function table"
"TABLE A" on page 25
"Preset function table"
the"Preset function table"
"Preset function table"
table".
and select a S2 DIP switches
and select a S2 DIP switches
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
Example: 0100
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
Example: 0110
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
Tabla de contenido
loading

Tabla de contenido