Tabella Di Programmazione Dei Dip Switch Per Funzioni Speciali; Dip Switch Special Function Programming Table; Tableau De Programmation Des Dip Switches Pour Fonctions Spéciales; Programmeringstabel Van De Dipswitches Voor Speciale Functies - Comelit Icom Manual Tecnico

Tabla de contenido
Codice /
Dip switch ON
Code
223
1,2,3,4,5,7,8
Comando serratura su SE in AC (default)
224
6,7,8
Comando serratura su SE in AC potenziata
225
1,6,7,8
Comando serratura su SE in DC
245
1,3,5,6,7,8
Tempo serratura: 2 sec + tono disattivo (default)
246
2,3,5,6,7,8
Tempo serratura: 4 sec
247
1,2,3,5,6,7,8
Tempo serratura: 8 sec
248
4,5,6,7,8
Tono conferma serratura: attivo
251
1,2,4,5,6,7,8
Relè C.NC.NO in parallelo a SE (default)
252
3,4,5,6,7,8
Apriporta sempre attivo (default)
253
1,3,4,5,6,7,8
Apriporta attivo solo per utente chiamato
Gestione comando attuatore
N.B. sull'impianto non deve essere presente
l'Art. 1256 in modalità attuatore generico.
Attivazione relè C.NC.NO su comando
229
1,3,6,7,8
attuatore: 2 sec
Attivazione relè C.NC.NO su comando
230
2,3,6,7,8
attuatore: 4 sec
Attivazione relè C.NC.NO su comando
231
1,2,3,6,7,8
attuatore: 8 sec
Comando attuatore su linea seriale S: disattivo
228
3,6,7,8
(default)
227
1,2,6,7,8
Comando attuatore su linea seriale S: attivo
232
4,6,7,8
Tempo di attesa risposta: 60 sec (default)
233
1,4,6,7,8
Tempo di attesa risposta: 180 sec
234
2,4,6,7,8
Tempo di attesa risposta: 30 sec
235
1,2,4,6,7,8
Tempo di conversazione: 90 sec (default)
236
3,4,6,7,8
Tempo di conversazione: 180 sec
237
1,3,4,6,7,8
Autoaccensione: attiva (default)
238
2,3,4,6,7,8
Autoaccensione: disattiva
Tono conferma su chiamata utente: attivo
239
1,2,3,4,6,7,8
(default)
240
5,6,7,8
Tono conferma su chiamata utente: disattivo
243
1,2,5,6,7,8
Tempo di attesa reset: 10 sec (default)
244
3,5,6,7,8
Tempo di attesa reset: 1 sec
249
1,4,5,6,7,8
Invio chiamata: singola (default)
250
2,4,5,6,7,8
Invio chiamata: tripla
Gestione posti interni collegati all'Art. 1622: fino
241
1,5,6,7,8
a 70 (default)
Gestione posti interni collegati all'Art. 1622: da
242
2,5,6,7,8
71 a 100
000
Simplebus (default)
255
1,2,3,4,5,6,7,8
Simplebus Top
254
2,3,4,5,6,7,8
IT
Serratura
Door lock command on SE in AC (default)
Door lock command on SE in enhanced AC
Door lock command on SE in DC
Door lock time: 2 sec + deactivation tone
(default)
Door lock time: 4 sec
Door lock time: 8 sec
Door lock confirmation tone: enabled
C.NC.NO relay in parallel with SE (default)
Lock-release always enabled (default)
Lock-release only enabled for user called
N.B. the system should not include Art. 1256
in generic actuator mode.
Enabling C.NC.NO relay on actuator control: 2
sec
Enabling C.NC.NO relay on actuator control: 4
sec
Enabling C.NC.NO relay on actuator control: 8
sec
Actuator control on serial line S: disabled
(default)
Actuator control on serial line S: enabled
Funzioni impianto
Awaiting response time: 60 sec (default)
Awaiting response time: 180 sec
Awaiting response time: 30 sec
Talk time: 90 sec (default)
Talk time: 180 sec
Self-ignition: enabled (default)
Self-ignition: disabled
Confirmation tone on user call: enabled (default)
Confirmation tone on user call: disabled
Reset wait time: 10 sec (default)
Reset wait time: 1 sec
Call transmission: single (default)
Call transmission: triple
Control of internal units connected to Art. 1622:
up to 70 (default)
Control of internal units connected to Art. 1622:
from 71 to 100
Modalità impianto
Simplebus (default)
Simplebus Top
Ripristino default
EN
Door lock
Actuator control management
System functions
System mode
Restore default
FR
Gâche
Commande gâche sur SE en CA (par défaut)
Commande gâche sur SE en CA intensifié
Commande gâche sur SE en CC
Temps gâche : 2 sec + tonalité désactivée (par
défaut)
Temps gâche : 4 sec
Temps gâche : 8 sec
Tonalité confirmation gâche : active
Relais C.NC.NO en parallèle à SE (par défaut)
Ouvre-porte toujours actif (par défaut)
Ouvre-porte actif uniquement pour usager
appelé
Gestion commande actionneur
N.B. l'Art. 1256 en modalité actionneur
générique ne doit pas être présent dans
l'installation.
Activation relais C.NC.NO sur commande
actionneur : 2 sec
Activation relais C.NC.NO sur commande
actionneur : 4 sec
Activation relais C.NC.NO sur commande
actionneur : 8 sec
Commande actionneur sur ligne série S :
désactivée (par défaut)
Commande actionneur sur ligne série S : active
Fonctions installation
Temps d'attente réponse : 60 sec (par défaut)
Temps d'attente réponse : 180 sec
Temps d'attente réponse : 30 sec
Temps de conversation : 90 sec (par défaut)
Temps de conversation : 180 sec
Auto-allumage : actif (par défaut)
Auto-allumage : désactivé
Tonalité confirmation sur appel usager : activée
(par défaut)
Tonalité confirmation sur appel usager :
désactivée
Temps d'attente reset : 10 sec (par défaut)
Temps d'attente reset : 1 sec
Envoi appel : simple (par défaut)
Envoi appel : triple
Gestion postes intérieurs reliés à l'Art. 1622 :
jusqu'à 70 (par défaut)
Gestion postes intérieurs reliés à l'Art. 1622 :
de 71 à 100
Modalité installation
Simplebus (par défaut)
Simplebus Top
Rétablissement réglage d'usine
11