Quick Programming; Special Key Programming - Comelit HFX-700W Manual Tecnico

Ocultar thumbs Ver también para HFX-700W:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

4.2.2 Quick programming

For the quick programming of the following functions:
• generic actuator (ACT)
• internal intercom calls (INT)
• internal paging calls (PAG)
• Self activation main external unit (AI)
• Automatic lock-release (Doctor mode) (D)
1
f Set the S2 DIP switches combination corresponding to the
functions that you want to programme for ALL KEYS as
shown in the

4.2.3 Special key programming

If the preset function do not reflect requirements, EACH KEY can be programmed differently by carrying out the steps below.
Special key programming allow to programm the following functions:
• generic actuator and coded actuator (ACT)
• internal intercom calls and general intercom calls to another user code (INT)
• internal paging calls and general paging to another user code (PAG)
• Self activation main external unit (AI)
• Automatic lock-release (Doctor mode) (D)
4.2.3.1 HOW TO PROGRAM THE ACTUATOR FUNCTION
Example:
key
Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
f Set S2 DIP-switch 5-6 to the combination 01
» the Privacy LED flashes
2
2.1 Choose the function: refer to the
combination in which the actuator function (ACT) is listed for the keys you wish to program.
2.2 Addressing:
f for generc actuator set S1 DIP switches to the combination 11111111
f for coded actuator set S1 DIP switches with the desired address in accordance with
"TAB. A" on page 26
3
Select the key to be associated with the function
f Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
4
Exit programming mode
f To exit programming mode, set S2 DIP switches 5-6 to the combination 00
» the Privacy LED switches off
5
When programming is complete,
f Set S2 DIP switches 1-2-3-4 to the combination 1111 (PROG setting). In this DIP switch
setting, the keys control the programmed functions; the NON-programmed keys control
functions referred to on line 0000
f Restore the user code setting on S1.
"4.2.1 Preset function
table".
"4.2.1 Preset function table"
("4.2.1 Preset function
Example
choose S2 DIP switches combination:
DIP 1
DIP 2
DIP 3
0
1
0
for set all the following function:
PAG /
INT
and select a S2 DIP-switches
table").
DIP 4
0
AI
NULL
ACT
ON
1 2 3 4
5
6 7
8
Example: 1010
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
21
Tabla de contenido