Changing Door Entry Monitor Ringtones; Configuration Ex-B; External Unit Addressing; Function Programming - Comelit HFX-9500M Manual Tecnico

Ocultar thumbs Ver también para HFX-9500M:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

4.5 CHANGING DOOR ENTRY MONITOR RINGTONES

1.
Keep the
button pressed until a confirmation tone is emitted (this operation is only possible with the system in stand-by; otherwise the
signalling LED will flash to warn the user)
2.
Press and release the
once (1 confirmation tone is emitted) to change the ringtone of calls from the external unit.
twice (2 confirmation tones are emitted) to change the ringtone for calls from the switchboard.
3 times (3 confirmation tones are emitted) to change the ringtone for intercom calls made from the internal unit.
4 times (4 confirmation tones are emitted) to change the floor door ("CFP") call ringtone.
Any further pressing of the
3.
Press and release button 1 to scroll through the various available ringtones in sequence.
4.
Press button 2 to confirm selection of the last ringtone heard and to exit (at any time) the monitor ringtone change mode. On exiting the
monitor ringtone selection mode a confirmation tone will be emitted.

4.6 CONFIGURATION EX-B

4.6.1 External unit addressing

„ Set the S1 DIP-switches corresponding to the address that you want to set as shown in the table below
EXTERNAL UNIT ADDRESSING
CODE
DIP 1
0
OFF
(default)
1
ON
2
OFF
3
OFF

4.6.2 Function programming

„ Set the S1 DIP-switches corresponding to the function that you want to programme as shown in the table below
DIP S1
ON
1 2 3 4
5
6 7
8
DIP 4
ON
*
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
DIP 5
ON
*
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
DIP 6
ON
*
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
DIP 7
ON
*
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
DIP 8
ON
*
1 2 3 4
5
6 7
8
* default
26
button:
repeats the sequence described above.
DIP 2
DIP 3
ON
OFF
OFF
1 2 3 4
5
6 7
8
ON
OFF
OFF
1 2 3 4
5
6 7
8
ON
ON
OFF
1 2 3 4
5
6 7
8
ON
OFF
ON
1 2 3 4
5
6 7
8
The lock-release relay and the second relay are controlled by 2 separate buttons (e.g. lock-release button and
actuator button)
The lock-release relay and the second relay are controlled by a single button (e.g. lock-release button)
lock-release activation time and relay activation time: 8 sec
lock-release activation time and relay activation time: 2 sec
confirmation tones (call, lock-release, relay, audio enabled): disabled
confirmation tones (call, lock-release, relay, audio enabled): enabled
Camera lighting LED: disabled
Camera lighting LED: enabled
reset wait time: 1 sec.
reset wait time: 10 sec.
FUNCTION
Tabla de contenido
loading

Tabla de contenido