II. OPERATING INSTRUCTIONS
All parts are factory-adjusted. Improper adjustments may result in failure.
If the unit is turned off, wait for at least 3 minutes before restarting the icemaker to prevent damage to the compressor.
This icemaker is designed to produce edible ice. To keep the icemaker hygienic:
* Wash your hands before removing ice. Use the plastic scoop provided (accessory).
* The storage bin is for ice use only. Do not store anything else in the bin nor use other electrical appliances in the bin.
* Clean the storage bin before use (see "III. 1. CLEANING").
* Keep the scoop clean. Clean it by using a neutral cleaner and rinse thoroughly.
* Close the door after removing ice to prevent entrance of dirt, dust or insects into the storage bin.
Operation Panel
[1] Display
run: Icemaking
oFF: Shut down
FUL: Bin full
cln: Cleaning
[2] Dot
Off: Normal mode
On: Sanitation mode (*)
* After 4 continued hours of inactivity, the icemaker automatically cleans
and refreshes the water circuit to prevent bacterial proliferation,
keeping it clean and sanitary for longer periods of time.
[3] ON/OFF Button / Down Button
[4] Cleaning Button / Up Button
[5] Reset Button / Enter Button
1. START UP
The installer will normally commission the icemaker to start the automatic icemaking process. To ensure continuous operation,
make sure that:
* The water supply tap is on,
* The icemaker is connected to the power supply, and
* The display shows "run".
2. USER SETTINGS
The settings listed below are adjustable by the user.
1) Press and hold the reset button for 3 seconds to enter the user setting mode. The display shows one of the setting codes.
2) Use the up or down button until the display shows the desired setting code. Then, press the enter button.
3) Use the up or down button to adjust the setting. Then, press the enter button.
4) After finishing the settings, use the up or down button until the display shows "END". Then, press the enter button to exit the
user setting mode.
Code
Item
U.04
Drain frequency
NOTICE
HYGIENE
Description
0: No drain
1: Every 1 cycle
2: Every 2 cycles
5: Every 5 cycles
10: Every 10 cycles
20: Every 20 cycles
7
[1]
[3]
ENGLISH
[2]
[5]
[4]
Default
10: Every 10
cycles