Implementación MIDI
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the VS-
890 resets all communication channels related with MMC.
When powered on the VS-890 transmits as the device ID 7FH.
GESCRITURA
Status
Data Bytes
F0H
7FH,Dev,06H,40H,
ccH,ddH,eeH,,,ffH,,,
Byte
Description
F0H
Status of Exclusive Message
7FH
Universal System Exclusive Message Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
40H
WRITE
ccH
Information Bytes follows the command
ddH
The name of the writable Information Field
eeH
Information Field Format
:
:
ffH
Field names and data
:
:
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the VS-
890 writes the data to the specified information field.
The VS-890 does not transmit the message.
GESCRITURA CODIFICADA
Status
Data Bytes
F0H
7FH,Dev,06H,41H,04H,
ddH,eeH,ffH,gg
Byte
Description
F0H
Status of Exclusive Message
7FH
Universal System Exclusive Message Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
41H
MASKED WRITE
04H
Number of Bytes follows the command
ddH
The name of the masked type writable Information Field
eeH
Byte number to write in the Bit Map
ffH
Bit location of the bit map byte to change
ggH
New data to write to the specified bit map byte
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the VS-
890 writes the data to the specified bit map byte.
The VS-890 does not transmit the message.
GLOCALIZAR (MCP)
❍Format 1 - LOCATE [I/F]
Status
Data Bytes
F0H
7FH,Dev,06H,44H,02H,00H,nnH
Byte
Description
F0H
Status of Exclusive Message
7FH
Universal System Exclusive Message Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
44H
LOCATE (MCP)
02H
Number of Bytes
00H
"I/F" sub command
nnH
Information Field (08H, 09H, 0AH, 0BH, 0CH, 0DH, 0EH, 0FH)
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the VS-
890 locates the selected time location stored to the specified information field.
124
Status
F7H
Status
F7H
Status
F7H
The VS-890 does not transmit the message.
❍Format 2 - LOCATE [TARGET]
Status
Data Bytes
F0H
7FH,Dev,06H,44H,06H,01H,
hrH,mnH,scH,frH,ffH
Byte
Description
F0H
Status of Exclusive Message
7FH
Universal System Exclusive Message Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
44H
LOCATE(MCP)
06H
Number of Bytes
01H
"TARGET" sub command
hrH, mnH, scH, frH, ffH
Standard Time with Sub Frame
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the VS-
890 locates the specified time location received from the command.
If the efficient locate switch [LOC?] or Marker switch [PREVIOUS], [NEXT] is pressed, the
VS-890 transmits as the device ID 7FH.
GDESPLAZAR
Status
Data Bytes
F0H
7FH,Dev,06H,4CH,02H,ddH,ssH
Byte
Description
F0H
Status of Exclusive Message
7FH
Universal System Exclusive Message Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
4CH
MOVE
02H
Number of Bytes
ddH
Name of the Efficient Destination Information Field
(08H,09H,0AH,0BH,0CH,0DH,0EH,0FH)
ssH
Name of the Efficient Source Information Field (01H)
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the VS-
890 transfers the data on the selected source information field to the destination Information
Field, if the name of both information fields is efficient.
The VS-890 does not transmit the message.
GCampo de información eficiente
The followings are the efficient Information Field on the VS-890.
The name of the efficient destination Information Field :
01H SELECTED TIME CODE
08H GP0 / LOCATE POINT
09H GP1
0AH GP2
0BH GP3
0CH GP4
0DH GP5
0EH GP6
0FH GP7
4FH TRACK RECORD READY
Status
F7H
Status
F7H