Led Diagnosis On The Bus Coupler; Reading The Diagnostic Display On The Bus Coupler; Conversion Of The Valve System; Valve System - Emerson AVENTICS Modbus TCP Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 93
Designation
Color
State
MOD (16)
Green Illuminated
NET (17)
-
Off
L/A 1 (18)
Yellow Flashes
1)
quickly
L/A 2 (19)
Yellow Flashes
1)
quickly
1)
At least one of the two LEDs L/A 1 and L/A 2 must be illuminated in green or be
illuminated in green and flash quickly in yellow. Depending on the data ex-
change, the flashing may be so fast that it appears that the LED is illuminated.
The color then appears to be light green.
If the diagnostic run is successful, you may commission the valve system. Other-
wise, the errors must be remedied, see section g 13. Troubleshooting.
Switch on the compressed air supply.
u

11 LED Diagnosis on the Bus Coupler

The bus coupler monitors the power supplies for the electronic components and
actuator control. If they exceed or fall below a set threshold, an error signal will
be generated and reported to the controller. In addition, the status is displayed
by the diagnostic LEDs.

Reading the diagnostic display on the bus coupler

The LEDs on the top of the bus coupler report the different messages. See
ble 16.
Before commissioning and during operation, regularly check the bus coupler
u
functions by reading the LEDs.
Fig. 14: Meaning of the diagnostic LEDs
Table 16: Meaning of the diagnostic LEDs
Designa-
Color
State
tion
UL (14)
Green
Illumi-
nated
Red
Flashes
Red
Illumi-
nated
Green/red Off
UA (15)
Green
Illumi-
nated
Red
Flashes
Red
Illumi-
nated
MOD (16) Green
Illumi-
nated
Green
Flashes
slowly
Green
Flashes
quickly
NET (17)
Green
Flashes
Green
Illumi-
nated
AVENTICS™ Modbus TCP | R412028202-BAL-001-AC | English
Meaning
The configuration is OK and the backplane is
working perfectly.
Network timeout
Connection with Modbus device on the fieldbus
connection X7E1
Connection with Modbus device on the fieldbus
connection X7E2
14
UL
15
UA
16
MOD
17
NET
18
L/A 1
19
L/A 2
Meaning
The electronics supply voltage is greater than the
lower tolerance limit (18 V DC).
The electronics supply voltage is less than the lower
tolerance limit (18 V DC) and greater than 10 V DC.
The electronics supply voltage is less than 10 V DC.
The electronics supply voltage is significantly less than
10 V DC (limit not defined).
Actuator voltage exceeds the lower tolerance limit
(21.6 V DC).
The actuator voltage is less than the lower tolerance
limit (21.6 V DC) and greater than UA-OFF.
The actuator voltage is less than UA-OFF.
The configuration is OK and the backplane is working
perfectly.
Module has not yet been configured
(there is no connection to a master)
The connection to the master exists, the IP address has
been received, but there is still no "connection" to the
master
"Param_Set" bit set
"Run_Set" bit set
Designa-
Color
tion
Red
Green/red Off
L/A 1 (18)
Green
Yellow
Green/yel-
low
L/A 2 (19)
Green
Yellow
Green/yel-
low

12 Conversion of the Valve System

Danger of explosion caused by defective valve system in an explosive at-
mosphere!
g Ta-
Malfunctions may occur after the configuration or conversion of the valve sys-
tem.
After configuring or converting a system, always perform a function test in
u
a non-explosive atmosphere before recommissioning.
This chapter describes the structure of the complete valve system, the rules for
converting the valve system, the documentation of the conversion, as well as the
re-configuration of the valve system.
The assembly of the components and the complete unit is described in
the respective assembly instructions. All necessary assembly instruc-
tions are included as printed documentation on delivery and can also
be found on the CD R412018133.

12.1 Valve System

The AV series valve system consists of a central bus coupler that can be extended
towards the right to up to 64 valves and up to 32 associated electrical compo-
nents. See also the section
Up to 10 input and output modules can be connected on the left side.
The unit can also be operated without pneumatic components, i.e. with only a
bus coupler and I/O modules, as a stand-alone system.
The following figure shows an example configuration with valves and I/O mod-
ules. See g Fig. 15.
Depending on the configuration, your valve system may contain additional com-
ponents, such as pneumatic supply plates, electrical supply plates, or pressure
regulators. See section
27
26
Fig. 15: Example configuration: unit consisting of AES series bus coupler and I/O
modules, and AV series valves
26
Left end plate
State
Meaning
Illumi-
Network timeout (30 seconds),
nated
Severe network problems,
IP address assigned twice
No diagnostic message
Illumi-
The physical connection between the bus coupler and
nated
network has been detected (link established)
Flashes
Data packets received (flashes for each data packet re-
quickly
ceived)
Off
The bus coupler does not have a physical connection
with the network
Illumi-
The physical connection between the bus coupler and
nated
network has been detected (link established).
Flashes
Data packets received (flashes for each data packet re-
quickly
ceived)
Off
The bus coupler does not have a physical connection
with the network
DANGER
g 12.5.3 Impermissible
configurations.
g 12.2 Valve
Zone.
32
30
29
28
35
32
I/O modules
33
34
38