Step 3. Water supply hose connection
Warning
-
Do not twist, crush or modify the water supply hose.
Fig. 7-8
Connect the water supply hose to the water inlet valve (Fig. 7) and to a cold water tap (Fig. 8)
as shown in the figures.
Note
Do not use tools for the connection, do it manually. Check the connection is firm.
Step 4. Drain hose connection
Warning
Do not kink or extend the drain hose.
-
Place the drain hose correctly; otherwise, there could be leaks.
-
You can connect the end of the drain hose in 2 ways:
1. To a drain. Fig. 9
2. In a drain pipe located in a sink. The pipe height must be between 60 and 100 cm. Fig. 10
Note
If the machine is equipped with a drain hose bracket, install it as shown in figure 11.
Warning
When installing the drain hose, fix it properly.
-
If the drain hose is too long, do not force it into the washing machine as it will cause
-
abnormal noises.

4. OPERATION

Quick Start
Warning
Before using the washing machine for the first time, make sure it is correctly installed.
-
Your device was thoroughly checked before leaving the factory. To remove any water
-
residue and to neutralise possible odours, it is recommended to clean the appliance before
using it for the first time. To do so, start the Cotton at 60ºC programme without laundry or
detergent.