  • ES

Idiomas disponibles

  • ESPAÑOL, página 3
5
Process data structure
WLL80
IO-Link
Process data
Bit 0 / data type
Bit 1 / data type
Bit 2 / data type
Bit 3 / data type
Bit 4 ... 15 / description/data type
Bit 16 ... 31 / description / data type
6
Troubleshooting
LED/fault pattern
Cause
Green LED does not light up
Voltage interruptions outside
the permissible range
Green LED flashes
IO-Link communication
Digital outputs not according
Parameter settings made
to graphic
manually, which deviate from
the standard
Signal interruptions when
Difference between the
object is detected
switch-on and switch-off
threshold (=hysteresis value)
is too small and/or the fluc‐
tuation of the light reflected
by the object is too large
for the configured hysteresis
value.
G U Í A D E I N I C I O R Á P I D O
Estas instrucciones únicamente son válidas junto con las instrucciones de uso
8026879. Puede encontrar las instrucciones de uso en www.sick.com.
Para los dispositivos WLL80-xxxxxSxx puede haber más información relevante
para la puesta en servicio. La encontrará en las instrucciones de uso.
La conexión, el montaje y el ajuste deben efectuarlos exclusivamente técnicos
especialistas.
No se trata de un componente de seguridad según la Directiva de máquinas de la
UE.
No instale el sensor en lugares directamente expuestos a la radiación solar o
a otras influencias climatológicas, salvo si las instrucciones de uso lo permiten
expresamente.
1
Elementos de mando y visualización
1 2
5
6
7 8
1
S
R
2
4 3
1 Bloqueo de la fibra óptica
2 LED amarillo: estado de recepción de luz Q1
3 LED verde: tensión de alimentación activa, Comunicación IO-Link
4 LED amarillo: estado de recepción de luz Q2
5 Indicación de fibra óptica correctamente introducida
6 Indicador
7 + 8 Tecla más/menos
9 Tecla de menú/OK
ß Aprendizaje / tecla Escape
2

Montaje

2.1 Funcionamiento a temperatura ambiente

–25°C ... +55 °C
–13°F ... +131 °F
8027404.1H1W/15.08.2022/de, en, es, fr, it, pl, pt, ru
A71
V1.1
4 bytes
Byte 0: Bits 31 ... 24
Byte 1: Bits 23 ... 16
Byte 2: Bits 15 ... 8
Byte 3: Bits 7 ... 0
Q
 / Boolean
L1
Q
 / Boolean
L2
Q
 / Boolean
int1
Q
 / Boolean
int2
Reserved
Analog value/signed integer (subindex: 120,
value:0)
Counter value/integer (subindex: 120, value:
18)
Measures
Ensure there is a stable
power supply in accordance
with the technical specifica‐
tions
-
Initiate a factory reset. The
digital outputs are reset to
factory settings.
Increase the hysteresis value
9
ß
OK
ESC
MENU TEACH
2.2 Conectar la fibra óptica
3
1
4
2
1.
Abrir el bloqueo de la fibra óptica 1.
2.
Introducir la fibra óptica 4 hasta el tope en las aberturas previstas (véase
símbolos de receptor y emisor en la carcasa) 2+5 (comprobar la indicación
de fibra óptica correctamente introducida 6).
3.
Cerrar el bloqueo de la fibra óptica 3.
IMPORTANTE
Si se usa una variante de palpador de fibra óptica con disposición coaxial de
las fibras, la fibra óptica de un solo hilo debe conectarse al emisor. La fibra
óptica de múltiples hilos (mazo de fibras) se conectará con el receptor.

2.3 Montar el sensor

e s
1
2.4 Ampliación de los módulos de bus
2
4
1.
Montar la unidad básica 2 sobre el carril DIN.
2.
Montar la pieza de terminación 4 justo a continuación de la unidad básica
en el carril DIN.
3.
Cerrar el conector hembra de la unidad de ampliación con la cubierta de
protección 3.
4.
Montar la unidad de ampliación 1 sobre el carril DIN.
5.
Deslizar la unidad de ampliación anexándola a la unidad básica 2 hasta
que el conector hembra de la unidad básica y el conector macho de bus 5
de la unidad de ampliación estén sólidamente en contacto.
3
Instalación eléctrica
Los sensores deben conectarse sin tensión.
3.1 CC
Dispositivo autónomo: U
Unidad básica + unidad de ampliación: U
6
5
2
1
5
: 12 ... 30 V CC
B
: 12 ... 24 V CC
B
3
WLL80 | SICK