21·Setting the time delay of feeding after successful
ignition, for example: start to feeding the pellets in 120s
after ignite successfully (Fig. 34)
Fig.34
*WHEN THE STOVE IS AUTOMATIC ASH CLEANING, THE STOVE WILL STOP , UNTIL THE ASH
CEALN FINISHED, STOVE WILL RESTART AUTOMATICALLY.
7.0 ERROR AND SOLUTION
Error Code
E1
E2
E3
E4
E5
E6 (water stove only )
E7 (water stove only )
Error Name
Room temperature
sensor failure
Flame sensor failure
Ignition failure
Burning grill wrong
position
Burning chamber
pressure abnormal
Water flow error
Water overheat
22·Setting the time delay for reignite after auto ash
22·Setting the time delay for reignite after auto ash
cleaning. For example: the stove will reignite in 180s
cleaning. For example: the stove will reignite in 180s
after finishing the auto ash cleaning. (Fig.35)
after finishing the auto ash cleaning. (Fig.35)
Fig
Fig
Possible Error
Room temperature
sensor is missing or
broken
Flame sensor is
missing or broken
1. The hopper is
empty
2. The feeder be
jammed by the pellets
Burning grill is not in
the right place
1. Hopper is open
2. Stove door is open
3. Stove inside air
leak
No water flow
1. Too much power
2. Water sensor
broken
26
Solution
Check or replace a the
room temperature
sensor
Check or replace a the
flame sensor
1. Reload the pellets
2. Check and clean
the feeding tube
1. Check the ash tray
if it's full
2. Restart the stove
and wait the stove
correct the position of
grill automatically
1. Close the hopper
2. Close the door
3. Check the inside
parts if air proof
1. check if the water
full filled the stove
2. Check the water
flow sensor
1. Reduce the power
2. Change the water
temperature sensor