Prevention Of Domestic Fires - HTW SKADI EPI-11SKABLACK Manual De Usuario E Instalacion

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

The clearance to a door, window or cavity must be at least:
- 1.5' (458 mm) below;
- 1.5' (458 mm) horizontally;
- 9'' (230 mm) above.
The clearance to fresh air intake for combustion of the pellet stove
or any other appliance, or the non-mechanical air supply inlet to the
building must be at least 4' (1.2 m).
The clearance to a mechanical air supply inlet to the building must be
at least 8' (2.5 m).
• The exhaust termination location (Fig. 20) must be at least:
- 1' (305 mm) above the ground level. Attention : the minimum vertical
rise shall always be not less than 5' (1.5 m).
Aflueat1'abovegroundisnotenfantsafe:westronglyreccomend
that the exhaust termination of flue be raised another 4' to avoid
injury.
- 7' (2.1 m) from a public walkway, but attention to where the vent
shall end its course,as it is not to be in between or serve two family
dwellings and/or directly above side-walks or paved driveways;
- 1' (305 mm) from the wall penetration point;
- 3' (915 mm) from a gas meter/regulator assembly;
- 3' (915 mm) from any adjacent combustibles such as:adjacent
buildings, fences, protruding parts of the structure, roof eaves or
overhangs, plants, shrubs, etc.
-The exhaust gases from the combustion of pellets fuel may
dirty the outside of the walls.
To avoid such possibility terminate the vent above the roof
line.
-Ensure that all installation work is carried out to professional
standards.

PREVENTION OF DOMESTIC FIRES

The product must be installed and used in compliance with the manufacturer's instructions and national standards as well as local regulations.
-When a flue pipe passes through a wall or a ceiling, special installation methods must be applied (protection, thermal insulation,
distances from heat-sensitive materials, etc.) See the paragraph from "INTERIOR VENT INSTALLATION" to "SHORT RISE INSTALLATION
- WALL OUTLET".
• It is also recommended that all elements made of combustible or inflammable material, such as beams, wooden furniture, curtaining, flammable
liquids, etc.be kept outside the heat radiation range of the stove and at a distance of at least 32" / 80 cm from the heating block.
• For other information, see the paragraph from "MINIMUM SAFETY DISTANCES" to "VENTING: TERMINATION REQUIREMENTS".
• The flue pipe,chimney stack, chimney and fresh air intake must always be free of obstructions,clean and checked periodically,that is,at least
twice during the seasonalperiod fromthe lighting ofthe stove andduring itsuse.Whenthe stove hasnotbeen used forsome time itis advisable
to carry out the checks mentioned above. For further information, consult a chimney sweep.
• Only use recommended fuels (See section "FUEL").
Fig. 20
CLEARANCETO WALL
PENETRATION POINT
CLEARANCE TO
COMBUSTIBLES
THIMBLE
90° ELBOW
13
CLEARANCE TO
PUBLIC
WALKWAY
7'
1'
3'
COMBUSTIBLES
45° ELBOW
WITH
TERMINATION
COLLAR
PUBLIC
1'
WALKWAY
CLEARANCE TO
GROUND
VENT
TEE
Tabla de contenido
loading

Tabla de contenido