Power Management
Use the following formula to convert voltage and amperage to
watts:
Volts × Amps = Watts
To prolong the life of your generator and attached devices, follow
these steps to add electrical load:
1. Start the generator with no electrical load attached.
2. Allow the engine to run for several minutes to get up to
temperature.
3. Plug in and turn on the first item. It is best to attach the item
with the largest load first.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.
Never exceed the specified capacity when adding loads to the
generator.
Eco (Economy) Mode
The Eco Mode button can be activated to turn on economy control
in order to minimize fuel consumption and noise while operating
the unit during times of reduced electrical output. Eco Mode
allows the engine speed to idle during periods of non-use.
The engine speed returns to normal when an electrical load is
connected. When the economy switch is off, the engine runs at
normal speed continuously.
ECO
NOTICE
For periods of high electrical load or momentary fluctuations,
the Eco Mode MUST be turned off.

Parallel Operation

The Champion model CPG4000DHY-EU is parallel ready and can
be operated in parallel with another Champion unit to increase
the total available electrical power. A Champion model 75500i-UK
parallel kit (sold separately) is required for parallel operation. For
a list of compatible models or to order a parallel kit, please call
customer service at +44(0)1942-715-407 or visit
www.championpowerequipment.co.uk
Detailed instructions for parallel kit installation and operation of
the connected generators are provided in the parallel kit operator's
manual.
Stopping the Engine
Remote Stop
1. Turn off all electrical connected loads. Never start or stop the
generator with electrical devices turned on.
2. Let the generator run at no-load for several minutes to
stabilize internal temperatures of the engine and generator.
3. Press the "STOP" button on the remote.
Engine will shut off but the START/STOP button will remain in
"STANDBY" mode for 12 hours and fuel valve will remain in the
"ON" position waiting for the next start instruction.
To completely shut down the generator, make sure the START/
STOP button is in "OFF" mode and no longer flashing green and
fuel valve is turned to "OFF" position when the generator will not
be used for an extended period of time.