Generator Location - Champion Global Power Equipment CPG4000DHY-EU Manual Del Operador

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 124
CPG4000DHY-EU - 3500W WIRELESS REMOTE START OPEN FRAME INVERTER
Failure to properly ground the generator can result in electric
shock.
A ground terminal connected to the frame of the generator has
been provided (see Controls and Features for terminal location).
For remote grounding, connect a length of heavy gauge
(12 AWG minimum) copper wire between the generator ground
terminal and a copper rod driven into the ground. We strongly
recommend that you consult with a qualified electrician to ensure
compliance with local electrical codes.
Neutral Floating*
– Neutral circuit IS NOT electrically connected to the frame/
ground of the generator.
– The generator (stator winding) is isolated from the frame and
from the AC receptacle ground pin.
– Electrical devices that require a grounded receptacle pin
connection will not function if the receptacle ground pin is not
functional.
Neutral Bonded to Frame*
– Neutral circuit IS electrically connected to the frame/ground of
the generator.
– The generator system ground connects lower frame cross-
member below the alternator. The system ground is connected
to the AC neutral wire.
* See your Specifications section for specified type of grounding.
WARNING
OPERATION

Generator Location

NEVER operate install a this generator inside any confined
spaces, building, garage, basement, crawlspace, shed,
vehicles, enclosure or compartment, including a generator
compartment of a recreational vehicle.
NEVER operate or start the generator in the back of an
SUV, camper, trailer, truck bed (regular sides, flat or other
configuration), under staircases, stairwells, next to walls
or buildings or in any other location that will not allow for
adequate cooling of the generator or for the proper exit of the
exhaust flow from the muffler system.
It is not recommended operating or storing this generator
in wet weather conditions such as rain or snow. Using a
generator in wet conditions could result in serious injury or
death due to electrocution. If it has to be used in damp or wet
weather a recommended covering needs to be used for safety.
In some state's generators may be required to be registered
with the local utility company when used at construction sites
and may be subject to additional rules and regulations, consult
your local municipal authority.
Generators should always be operated on a flat, level surface
at all times (even when not in operation).
Generators must have a minimum of 5 feet (1.5 m) of
clearance from all combustible material.
Generators must also have a minimum of 3 feet (91.4 cm)
of air flow clearance on all sides to allow for adequate
performance cooling, maintenance and servicing.
Always place the generator in a well-ventilated area. NEVER
place the generator near air intake vents or where exhaust
fumes could be drawn into occupied or confined spaces.
Always carefully consider wind and air currents when
positioning generator.
Always allow generators to properly cool before transport or
for storage purposes.
Failure to follow proper safety precautions may result in
personal injury, damage to the generator and void the
manufacturer's warranty.