8 Putting out of operation
Symbol
Designation
Key-operated switch S2 (4) Fig. (11)
Auto
Switching state Automatic: Wire feed is functional without restriction with the cover (M-Drive) closed
Hand
Switching state Manual: The protective device is bridged. The Inching (wire feed) function is enabled with cover
(M-Drive) open. In any other possible situation, the drives remain currentless, and the start signal is interrupted.
Inching trigger S3 (3) Fig. (11) or S7 (6) Fig. (12)
Press trigger, to feed wire
Init trigger S4 (2) Fig. (11) or S9 (16), Fig. (12)
After eliminating fault, press trigger. Internal control is reset to starting position.
Slave LED V2 (15) Fig. (11)
Status green = ready, status red = fault
Master LED V1 (1) Fig. (11)
Status green = ready, status red = fault
Gas test trigger S8 (1) Fig. (12)
Press trigger for gas flow.
8 Putting out of operation
1 Switch E-Box and M-Drive to currentless state on the main switch (6) .
Fig. 11 E-Box operating elements on page EN-15
9 Maintenance and cleaning
Regular and lasting maintenance and cleaning are the prerequisite of a long life and a trouble-free function.
In doing so, observe the following:
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, servicing, dismounting and repair work, the following instructions
must be adhered to:
• Switch off the power supply.
• Disconnect the compressed air supply.
• Pull the mains plug.
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation.
• Replace any damaged, deformed or worn parts.
Danger of crushing
Limbs can be drawn in and crushed.
• Do not reach into moving wheels.
NOTE
• The maintenance intervals given are recommended values and refer to single-shift operation.
• Maintenance and cleaning work may only be carried out by qualified and trained specialists.
• Always wear your personal protective clothing when performing maintenance and cleaning work.
EN - 16
DANGER
DANGER
WARNING
MFS-V2