ENGLISH
KEY PARTS AND FUNCTIONS
1. Compressor (pump) unit - Pull in and compresses the
atmospheric air.
2. Air tank - Stores the compressed air.
3. Electric motor - Makes the compressor unit run.
4. Pressure switch - Controls the operation of compressor to avoid
that the maximum working pressure is surpassed. See Installation
and Electrical connection chapter.
5. Safety Valve - Automatically exhausts the tank in case the
pressure is above the maximum allowed.
6. Check Valve - Keeps the compressed air inside the tank avoiding
its return when the compressor unit stops.
7. Drain - Removes the condensed water that accumulates inside the
tank.
8. Pressure gauge - Shows the pressure inside the tank in psi or bar.
9.
Pressure regulator with valve
on the indicator panel.
10.
Protecting Screen
- Protects the rotating parts.
11. Intercooler - Carries and cools down the compressed air.
12. Air filter - Filters atmospheric air impurities that are sucked by the
compressor.
13. Valve - Controls the compressed air release, connects the hose
nozzle.
14. Oil drain plug - Allows the removal of lubricant oil.
15.
Oil gauge dipstick - Shows the oil level and allows its replacement.
16. Identification tag/Information sticker - Shows the compressor's
technical data.
17. Tank's identification tag - Shows the tank's technical data.
18. Wire
with plug (2P+GR)
to connect the compressor to
the electric supply.
19.
On/Off button - Starts/shuts off
the compressor.
20. Rubber feet - Used for the
support of the compressor set.
21.
Wheels - Help to move the
compressor.
22.
Hose nozzle - Used to connect
the hose to the compressor, to
accessories or hose nozzle
(not shown).
19
8
4
9
13
22
- Used to adjust working pressure
- Used
1
3
14
2
18
16
5
20
7
17
INSTALLATION
1. Assembly: Remove the product from the packaging and rubber feet
(Picture 2)
2. Location:
Install the compressor in a covered, well ventilated area,
free of dust, gases, toxic gases, humidity or any other kind of pollution.
The ambient temperature recommended during work is: minimum of
5°C (41°F) and maximum of 40°C (104°F). In order to avoid damage to
the compressor, operate it on a level foundation.
2.1
Compressor's installation When this compressor model is
coupled to a compressed air network, the connection must be made by
a hose or expandable joints so that the charges, thermal expansion,
piping's weight, mechanical and thermal shocks or obstructions are
not transmitted to the air receiver. The air receiver may be damaged if
these warnings are not observed.
3. Position: Keep a minimum distance of 800 mm (32") from any
11
obstacle, to allow good ventilation during operation and to make
maintenance easier.
4. Quality of compressed air: For services in which the air must be free
of oil or dust particles, the installation of special air filters. Please
15
contact the nearest Black&Decker Authorized Service Center for
information.
5.
Electrical connection:
5.1
Look for a specialized
technician to evaluate
the electrical supply
and to select the
adequate protection
and input devices.
(Installation conform
Picture 3)
12
3
11
Fuse type "D" or
F1
"NH"(see Table 2 - page 23)
6
P
Pressure switch
M
Electric motor
21
PICTURE 3
22
PICTURE 2
:
Customer' s responsibility
Tension
Supplies
Ground
Phase
Neutral
F1
PLUG2P+GR
N
OR WIRE
P
M
1~