Problem
Tank pressure increases quickly or too frequent starts
(The normal number of starts is roughly 6 an hour)
Code
19, 24
Problem High temperature of the compressed air
Code
5, 6, 8, 9, 10, 11, 12, 13, 20
Problem Compressor operate ininterruptedly
Code
6, 8, 13, 25
Problem
Excessive consumption of lubricating oil
(Compressors usually use more oil in the first 200 working
hours until rings are smoothly adjusted)
Code
6, 10, 12
Problem Lubricant oil with unusual color
Code
10, 15, 16, 21
Problem Insufficient pressure for required work
Code
15, 18, 24
Problem Air leakage through relief valve of pressure switch or
compressor unit (when assembled), with compressor
operating from more than 1 (one) minute (valve closes above
20 psi (1.3 bar))
Code
25
POSSIBLE CAUSE
COD
1
Voltage drop or electrical
supply is out
2
Damaged electric motor
3
Tank is full of air
4
Installation fuse has
burned out
5
Check valve does not seal
because of impurities
6
The demand is above the
compressor's capacity
7
Thermal protector tripped
(Picture 11 - page 25)
8
Filter clogged
9
Air leakage in the
compressor
10 High ambient temperature
(max. 40°C or 104°F)
11 Valve plate joint is broken
12 Wrong oil or low oil level
13 Carbonized valve plate
POSSIBLE SOLUTION
Check the installation and/or wait
for the electrical supply stabilization
Send it to the nearest
Black&Decker Authorized
Service Center
Electric motor will start as soon as
the pressure in the tank decreases
Find out the burning cause
(see Table 2 - page 23)
Send the compressor to the
nearest Black&Decker
Authorized Service Center
Check the compressor's capacity
Turn compressor off, wait for 5 (five)
minutes and reset the protector .
If tripping is frequent, look for the
nearest Black&Decker Authorized
Center
Replace it
Re-fasten bolts and/or fittings
Improve local conditions
Look for the nearest Black&Decker
Authorized Center
Change oil
Clean it every 1000 working hours
or 12 months at your nearest
Black&Decker Autorized Service
Center.
POSSIBLE CAUSE
COD
14
Deficient or inadequate
electrical supply
15
Operating in a
non-adequate environment
16
The oil change did not
occur at the recommended
interval
17
Loose fastening elements
18
Continuous air leakage
through pressure switch's
relief valve when
compressor shuts off
(Picture 11 - page 25).
19
Excess water in the tank
20
Too much dust and paint
on the compressor
21
Water is mixed with the oil
(milky coloration)
22
Ambient temperature
below minimum
recommended 5°C (41°F)
23
Operating too long below
pressure of 60 psi (4.0 bar)
24
Pressure regulator valve
not adjusted
25
Relief valve not seal
because of impurities
(Picture 11 - page 25)
26
POSSIBLE SOLUTION
Have a specialized technician
check it
Improve local conditions
See Table 4 - page 25 (Preventive
maintenance) the oil change
intervals
Find and re-fasten them
Send compressor to the nearest
Black&Decker Authorized Center
Drain the tank through the drain as
indicated in Picture 8 - page 24
Clean the compressor externally
Change the lubricant oil and run
your pressure compressor for
15 min, at a maximum pressure of
100 psi (7.0 bar). This will remove
any internal condensation signs
inside pump
Run the equipment above 5°C
(41°F)
Compressed air consumption
higher than compressor's flow
Adjust it (Picture 8 - page 24)
Send compressor to the nearest
Black&Decker Authorized Center