Before installation
Make sure that:
• the work surface is level and that no components interfere with the space
requirements of the unit.
• the work surface is made of heat-resistant and insulating material.
• that an oven, if the appliance is installed above it, has a built-in cooling fan.
• a suitable circuit breaker, which allows complete disconnection from the supply
mains, has been integrated and mounted in the standing wiring in accordance with
the local wiring regulations.
• the circuit breaker is of the approved type and has a contact opening of 3 mm
between all poles (or in all active (phase) conductors if local regulations permit).
• the circuit breaker is easily accessible to the user of the induction hob.
• Contact the local building authorities if you have any doubts about the installation.
• Apply heat-resistant and easy-to-clean materials (such as ceramic tiles) to the walls
surrounding the induction hob.
After installation
Make sure that:
• the mains cable is not accessible through cupboard doors or drawers.
• fresh air access to the underside of the unit is ensured so that air exchange can take
place.
• a heat shield is fitted underneath the appliance when the appliance is installed
above drawers or cupboards.
• the circuit breaker is easily accessible to the user of the induction hob.