 Empty the pump by pulling on the starter grip and rope
about 6 times. This should remove most of the liquid from
the pump.
NOTICE:
The use of a pump protector is required after each use
and before storing to prevent cold weather and seal
damage during storage. Failure to use pump protector
will void your warranty.
 Drain the lubricant and replace with fresh, clean lubricant
as described in Changing Engine Lubricant earlier in
this manual.
 Disconnect spark plug wire and remove the spark plug.
Pour about a teaspoon of clean, air-cooled, four-cycle
lubricant through the spark plug hole into the combustion
chamber.
 Leaving the spark plug out, pull the starter grip and rope
two or three times to coat the inside of the cylinder wall.
 Inspect the spark plug and clean or replace, as necessary.
 Reinstall the spark plug, but leave the spark plug wire
disconnected.
PERIODIC MAINTENANCE SCHEDULE TABLE
NOTE: If a separate engine manual is provided for this pressure washer, please follow the maintenance schedule provided
in the engine manual instead of the maintenance information listed below.
Maintenance Items
Clean engine & check bolts & nuts
Check engine lubricant
Change engine lubricant
1
Check water inlet filter placement
Add fuel stabilizer
Add pump protector
Clean spark plug
Clean air cleaner
Replace air cleaner element
Clean & adjust spark plug & electrodes
Replace spark plug
Remove carbon from cylinder head
Check & adjust valve clearance
Initial lubricant change should be performed after the first 20 hours of operation. Do not pour old lubricant down
1
sewage drains, into garden soil, or into open streams. Your local zoning or environmental regulations will give you more
detailed instruction on proper disposal.
If water inlet filter is missing or damaged, it must be replaced. See Replacement Parts List available online or call customer
2
service for part number to order.
Have performed by your nearest qualified service center
3
MAINTENANCE
Each
use
X
X
X
2
X
X
X
3
3
Page 16 — English
 Clean the air filter.
 Extend the starter grip and rope to check its condition.
If the rope is frayed, have it replaced immediately by an
qualified service center.
 Remove all hoses. Coil the hoses and store as shown.
Do not allow the hose to become kinked.
 Pull the handle release knob out and lower the handle to
the down position.
 Store the unit and accessories in an area that does not
reach freezing temperatures. Do not store near furnace or
other sources of heat that could dry out the pump seals.
PREPARING FOR USE AFTER STORAGE
 Pull the starter grip and rope three or four times to clean
lubricant from the combustion chamber.
 Remove spark plug from the cylinder. Wipe lubricant from
the spark plug and return it to the cylinder.
 Reconnect the spark plug wire.
 Refuel the machine as described earlier in the operator's
manual.
Every
Every
Every
8 hrs.
20 hrs.
50 hrs.
X
X
Every
Every
100 hrs.
300 hrs.
X
X
X
X
X
X