Bosch MIC-ALM-WAS-24 Manual De Instalación página 15

Ocultar thumbs Ver también para MIC-ALM-WAS-24:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 60
MIC Alarm-Washer Interface Unit
Pin
1
2
3
7. Connect Alarm inputs and outputs, if desired.
Pin
1
2
3
4
5
6
7
8
9
10
11
12
8. Connect the washer pump drive, if desired.
Bosch Security Systems
Description / Function
24VAC
Chassis Ground
24VAC
Check that the connections are secure.
Prepare the cable as needed.
Select the cable gland in the most suitable location based on installation conditions. Item
14 is recommended.
If you selected the gland location identified as item 14, remove the M16 plug; insert in its
place the extra cable gland (supplied) for the alarm input / output interface.
Feed the cable through the cable gland into the enclosure.
Make the connections for the alarm inputs (for external devices such as door contacts or
sensors) and alarm outputs (for switching external units such as lamps, alarm sirens, or
other alarm units) to terminal block P101 (item 6) according to the table below.
Note 1: Pins are numbered from right to left on terminal block P101.
Note 2: Any of the GND terminals can be used with any alarm input/output.
Description / Function
Alarm Input 1
Alarm Input 2
Alarm Input 3
Alarm Input 4
Ground
Alarm Output 1
Alarm Output 2
Alarm Output 3
Ground
Tamper Alarm 1
Tamper Alarm 2
Ground
Check that the connections are secure.
If tamper alarm inputs are used, attach a 2.2 K ohm end-of-line termination near the alarm
contact.
Prepare the cable as needed.
Select the cable gland in the most suitable location based on installation conditions. Item
12 is recommended.
Feed the cable through the cable gland into the enclosure.
Make the connections to terminal block P100 (item 10) according to the table below.
Installation Manual
Installation | en
LED
AI1
AI2
AI3
AI4
AO1
AO2
AO3
2014.09 | 1.3 | F.01U.305.934
15
Tabla de contenido
loading

Tabla de contenido