OPERATING AND MAINTENANCE MANUAL
HORIZ. CENTRIFUGAL ELECTRIC PUMP CX SERIES
6) The pump must be installed in ventilated and frost-protected locations.
7) If the pump is installed outdoors, the ingress of water into the electrical elements should be preven-
ted.
8) The electrical connection device should protect the pump against damage due to phase failure,
voltage failure or overcurrent.
9) For better performance and to minimise noise and vibrations, the installation of silent blocks should
be considered.
5. TRANSPORTATION
The machines in question shall be supplied in suitable packaging to ensure proper protection during
all stages of transport. If, on receipt of the goods, the packaging is damaged, it is necessary to ensure
that the machine has not been damaged during transport and that it has not been tampered with.
In the event of damage to the equipment or if any part of the machine is found to be missing, the
transporter and the manufacturer must be notified immediately and the corresponding photographic
documentation must be provided. Materials used to protect the equipment during transport must be
disposed of using the disposal channels existing in the country of destination.
6. LIFTING AND MOVING
For all lifting and moving operations, the operator must use the minimum personal protective equip-
ment required for the operations to be carried out (safety footwear, gloves and protective helmet).
Machines with a weight of more than 25 kg must be moved using suitable moving systems with a
capacity greater than the weight of the machine to be handled (see the weight indicated on the pac-
kaging). If it is necessary to use belts for handling the machine, these must be in good condition and
must be of adequate strength for the weight of the machine to be handled.
Pumps weighing <25 kg may be lifted manually by the operator without the aid of lifting equipment.
9
ENG