1.4 Settings
1.4.1 Setting the burner power manually
Use the knob (3 fig. 1) to select the heater power. You
may choose between the minimum, maximum, and in-
termediate positions, depending on the required heating
power.
If the knob is turned counterclockwise, the unit will ope-
rate at maximum power. If the temperature is too high,
for example in the summer, or if you need a reduced
flow of not very hot water, turn the knob clockwise. This
reduces the power, and therefore the gas consumption.
In the ● position, the unit is turned off.
1.4.2 Setting the temperature
Turn the water temperature selector clockwise to incre-
ase the temperature, or counterclockwise to decrease it.
fig. 4 - Setting the temperature
1.5 Faults
Once the adjustments described above have been made,
the heater is ready to operate automatically. When a hot
water tap is opened, an intermittent discharge is genera-
ted on the ignition electrode to light the burner.
All electronic models have an ionization electrode built
into the burner to monitor flame presence. If a malfun-
ction or lack of gas causes the heater to turn off, close
the hot water tap.
It is then necessary to eliminate the fault or obstacle pre-
venting the gas from reaching the heater, e.g., inadver-
tent closing of the gas cock, empty gas cylinder, etc.
To reactivate the heater, close and open the hot water
tap.
If no hot water is produced after eliminating the cause
and opening the hot water tap, repeat the process.
If the problem persists, call the technical support center.
Table 1 - Faults
58
EN
The burner
does
ignite
A c t i v a t i o n
of the over-
temperature
protection
Activation of
the flue gas
thermostat
(after
o p e r a t i o n ,
the unit is
reset by tur-
ning on the
tap, and the
thermostat
cools off).
cod. 3542C090 - Rev. 01 - 09/2022
Absence
of
Check the flow of
not
gas
gas to the heater,
and make sure the
pipes have been
purged.
Failure of the
Check the elec-
ignition/detec-
trode cable, and
tion electrode
make sure it's pro-
perly
and free of depo-
sits.
Defective gas
Check
valve
change the gas
valve.
Damaged or
Check that the
badly positio-
heating
ned
heating
is properly instal-
sensor
led and operating
and/or change it.
Flue gas ther-
Check the thermo-
mostat
con-
stat.
tact open
Cables
di-
Check the con-
this
sconnected
nections.
T h e r m o s t a t
Check the thermo-
obstructed or
stat.
incorrectly si-
zed
Probe discon-
Check the con-
nected
nection or change
the probe.
CADI
connected
and/or
sensor