Not possible to switch on: contact Festool
service workshop.
7.5
AutoClean – cleaning the main filter
(variants with AutoClean only)
Only in conjunction with a disposable
bag (to comply with dust class "L"). Not
for use during wet extraction.
Automatic dedusting
Activate AutoClean or set the frequency using
the rotary knob [1-7] (depending on the mobile
dust extractor variant).
Manual dedusting
Turn the switch [1-8] to the AC symbol.
Full manual cleaning
► Cover the end of the nozzle or suction hose
with your hand or CT-VS closing slide for
two seconds.
► Turn the switch [1-8] to the AC symbol.
8
Working
8.1
Handling
Hose holder: After finishing work, you can feed
the suction hose through the opening [8-2] and
place it in the hose holder.
SysDoc Systainer storage area: A Systainer can
be fastened to the storage area with the four
slides or the T-Loc lock [8-1].
8.2
Extracting dry materials
CAUTION
Hazardous dust
Damage to the respiratory passage
► Always use a filter or disposal bag!
When extracting dust that exceeds the
permitted limit values, only extract from
a single machine (electric or air tool).
Observe the following when extracting dust
generated by operating electric power tools:
Ensure there is adequate ventilation! Observe
regional regulations!
Limit values: exhaust air max. 50% of the clear
air volume
Formula: room volume V
8.3
Extracting wet materials/liquids
Remove the filter/disposal bag.
Use a special wet filter (NF-CT).
The dust extraction stops automatically when
the maximum fill level is reached.
18
x air renewal rate L
R
It must be ensured that the machine (main fil
ter, suction hose, container, etc.) is sufficiently
dried after extracting wet materials.
Hazardous dust
Damage to the respiratory passage
► After extracting wet materials, remove the
wet filter and replace it with the main filter
for dry materials.
Escaping foam and liquids
► Switch off and empty the machine immedi
ately.
8.4
After finishing work
► Variants with AutoClean only: Clean the
main filter automatically or manually (see
section 7.5)
► Switch off the mobile dust extractor and
pull out the mains plug.
► Wind up the mains power cable.
► Empty the dirt trap.
► Place the mobile dust extractor in a dry
room inaccessible to unauthorised users.
9
Service and maintenance
Risk of injury, electric shock
► Always pull the mains plug from the socket
before performing any servicing and main
tenance work.
► All maintenance and repair work which re
quires the motor housing to be opened
should always be carried out by an author
ised service workshop.
Customer service and repairs must only be
carried out by the manufacturer or service
workshops: Find the nearest address at: