We recommend cleaning the main filter complete-
ly if severely clogged:
Cover the end of the nozzle or suction hose with
your hand for 2 seconds.
Turn the switch [1-9] to the AC symbol.
When the CT-VS closing slide is used (order no.:
497926), the filter can be cleaned fully without
removing the connected electric power tools.
In intensive applications that generate adherent
dust, it may be necessary to clean the filter element
Handling
Hose store: after finishing work, you can feed the
suction hose through the recess [4-3] and place it
in the hose store. You can do the same with the
mains cable through the other recess [4-2].
SysDoc Systainer attachment system: a Systainer
can be attached to the storage area via the two
slides [4-1].
4
4-1
Extracting dry materials
WARNING
Not suitable to vacuum hazardous or toxic sub-
stances or dusts e.g. asbestos.
The filters will not be able to capture all particles
and may exhaust them back into the environ-
ment.
Remember: A damp main filter will clog more
quickly when dry materials are extracted. There-
fore, dry the main filter before extracting dust or re-
place the damp filter with a dry one.
12
mechanically under certain circumstances (ex-
tract). Wear a dust mask!
Folding out the brake lever [1-13] prevents the mo-
bile dust extractor from rolling. To achieve this, lift
the front end of the mobile dust extractor slightly
and push the brake lever downwards until it latches
into place. Push the lever [1-12] again to release.
Working
Risk of injury
Do not evacuate combustible liquids!
The main filter shall only be used for extracting
dry materials.
Before extracting fluids, remove the filter or dis-
posal bag (see chapter Changing the filter bag
4-2
and Changing the disposal bag). We recommend
using a special wet filter.
The dust extractor stops automatically when the
maximum level is reached.
4-3
Escaping foam and fluids
Switch off the machine immediately and empty
the dust container.
Special features of the CT 36 E AC- LHS
To use the mobile dust extractor in combination
with the PLANEX:
Use kink-resistant suction hose D 36 mm x 3.5
m-AS.
Use a special suction sleeve for connecting the
PLANEX.
Use closing slide CT-VS between the intake
opening [1-1] and suction hose.
Attach the tool holder.
Always use with a disposal bag!
Applying the brake
Extracting fluids
WARNING
CAUTION