Electrical Connection - BRENNTAG HEATSAVR Manual De Instalación

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

2.3

Electrical Connection

Ent er
Pr o g
Esc
Set
1) Connect the power supply cable to the power supply or receptacle (100.......240 Vac) using appropriate
plug.
2) It is a dry contact, works after, before or with the dosage, it is used to control an external system.
3) You can connect the external signal (24....240 Vac) to the Flow connector, this inlet is connected to the
Flow function, if enabled (ON) it allows the dosing to be activated when the external signal is present.
4) You can connect the level probe (optional) to the "Level" connector.
2.4
Switch ON system
When the system is switched ON, it will ask the following settings:
1. Language (you can choose EN, IT, FR, DE, ES).
2. Clock Setup
3. Unit (you can choose ml or oz).
2.4
Priming
With the right-hand switch in the ON (I) position (system operating), press the UP (+) key for at least 2 seconds
until the pump starts to run at the max speed, press again to stop the pump.
2.5
Standby position
With the right-hand switch in the OFF position (O position), the system is in standby mode and programs will not
run. This function is needed for maintenance or alarm, without powering down the system.
The system must be ON (I position) for normal timed operating.
H E A TS A V R
N ot Used Not Used
C od e 0000137248
2
Relay
3
4
Flow
Level
External signal
24....240 Vac
Enter
Prog
Esc
S et
Standby switch
1
L
N
100...240 Vac
rev . 1 . 0
3