2 – slow-down to 33% of normal speed.
3 – slow-down to 25% of normal speed.
10.2) LOGIC MENU (logic. )
-
TCA (TCA) [ OFF ]
ON
Activates automatic closing
OFF Excludes automatic closing
-
3 Steps (3 step) [ OFF ]
ON
Enables 3-step logic. A Start impulse has the following effects:
door closed:..........................................................................................opens
on opening:................................stops and enters TCA (if configured)
door open:..............................................................................................closes
on closing:.....................................................................stops and reopens
OFF Enables 4-step logic. A Start impulse has the following effects:
door closed:...........................................................................................opens
on opening:................................stops and enters TCA (if configured)
door open:..............................................................................................closes
on closing:...................................stops and does not enter TCA (stop)
after stopping: .....................................................................................opens
-
Impulse lock (ibl open) [ OFF ]
ON
The Start impulse has no effect during the opening phase.
OFF The Start impulse becomes effective during the opening or
closing phase.
-
Rapid closing (fast cls) [ OFF ]
ON
Closes the gate after photocell disengagement, before waiting for
the end of the TCA set.
OFF Command not entered.
-
Photocells on opening (photc. open) [ OFF ]
ON
In case of obscuring, this excludes photocell operation on opening.
During the closing phase, it immediately reverses the motion.
OFF In case of obscuring, the photocells are active both on opening
and on closing. When a photocell is obscured on closing, it reverses
the motion only after the photocell is disengaged.
-
Photocell test (test phot) [ OFF ]
ON
Activates photocell check
OFF Deactivates photocell check
If this setting is not activated (OFF), it inhibits the photocell che-
cking function, allowing connection of devices not provided with
additional checking contact.
-
Gate-open or 2nd radio channel warning light (SCA 2ch) [ OFF ]
ON
The output between terminals 25 and 26 is configured as gate-
open warning light, in this case the 2nd radio channel controls
pedestrian opening.
OFF The output between terminals 25 and 26 is configured as 2nd
radio channel.
- Motors in operation (1 mot ON) [ OFF ]
ON
Only motor 2 is in operation (terminals 1 and 2).
With this configuration, the pedestrian input is disabled.
OFF Both motors are in operation.
- Lock hold (bloc persist) [ OFF ]
ON
To be used when opening and closing mechanical backstops
are fitted.
This function activates leaf pressure on the backstop, without this
being considered as an obstacle by the ampere-stop sensor.
Then the leaf continues its stroke for another 0,5s, after intercep-
ting the limit switches. Therefore the limit switches are triggered
slightly in advance, and the leaves will stop perfectly on the end
stop plate.
OFF To be used when no mechanical backstops are fitted.
Movement is exclusively stopped by the limit switches being trig-
gered; in this case it is necessary to set the opening and closing
limit switch triggering point with precision.
- Prealarm (preal) [ OFF ]
ON
The blinker comes on about 3s before the motors start.
OFF The blinker comes on at the same time as the motors start
- Fixed code (fixed code) [ OFF ]
ON
The receiver is configured for operation in fixed-code mode, see
paragraph on "Radio Transmitter Cloning".
OFF The receiver is configured for operation in rolling-code mode, see
paragraph on "Radio Transmitter Cloning".
- Radio transmitter programming (radio prog) [ ON ]
ON
This enables transmitter storage via radio (REPLAY, CLON
1 – First press the hidden key (P1) and then the normal key (T1, T2,
T3 or T4) of a transmitter already memorised in standard mode
by means of the radio menu.
20 -
VIRgO
www.metalines.com
INSTALLATION MANUAL
2 – Within 10s press the hidden key (P1) and the normal key (T1,
T2, T3 or T4) of a transmitter to be memorised.
The receiver exits the programming mode after 10s, other new
transmitters can be entered before the end of this time.
This mode does not require access to the control panel.
OFF This disables transmitter storage via radio.
The transmitters can only be memorised using the appropriate
Radio menu.
Wireless memorizing disabled: wireless learning of any remote
control disabled (including CLONI and REPLAY).
- Motor logic reversal (change mot. ) [ OFF ]
ON
Mot.1: it is the first to start on opening and the last to start on closing.
Mot.2: it is the last to start on opening and the first to start on closing.
OFF Mot.1: it is the last to start on opening and the first to start on closing.
Mot.2: it is the first to start on opening and the last to start on closing.
10.3) RADIO MENU (RADIO)
-
Add
Allows you to add one key of a radio control device to the receiver
memory; after storage it displays a message showing the receiver
number in the memory location (from 01 to 64).
Add Start button (add start)
associates the required key to Start command
Add 2ch button (add 2ch)
associates the required key to 2nd radio channel
-
Read (read)
Checks one key of a receiver; if stored it displays a message showing
the receiver number in the memory location (from 01 to 64), and the
key number (T1, T2, T3 or T4).
-
Eliminate list (erease 64)
WARNING! Completely removes all memorised radio control devices
from the receiver memory.
- Receiver code reading (RX code)
This displays the code entered in the receiver.
Consult paragraphs 12-13-14-15 for further information concerning
the advanced functions of the Clonix incorporated receiver.
10.4) LANGUAGE MENU (language)
Allows you to set the language on the display programmer.
-
ITALIAN (ITA)
-
FRENCH (FRA)
-
GERMAN (DEU)
-
ENGLISH (ENG)
-
SPANISH (ESP)
10.5) DEFAULT MENU (default)
Restores the preset default values on the control unit. After restoring, a
new autoset operation must be carried out.
10.6) DIAGNOSTICS AND MONITORING
The display on the LINX panel shows some useful information, both
during normal operation and in the case of malfunctions.
Diagnostics:
In the case of malfunctions, the display shows a message indicating
which device needs to be checked:
PED
= PED input activation
STRT
= START input activation
STOP
= STOP input activation
PHOT
= PHOT input activation
FLT
= FAULT input activation for checked photocells
SWO1
= activation of Motor 1 opening limit switch input
SWC1
= activation of Motor 1 closing limit switch input
SWO2
= activation of Motor 2 opening limit switch input
SWC2
= activation of Motor 2 closing limit switch input
In the case where an obstacle is found, the LINX panel stops the door
and activates a reverse manoeuvre; at the same time the display shows
the "AMP" message.
Monitoring:
During the opening and closing phases, the display shows four digits
separated by a dot, for example 35. 4 0. The digits are constantly updated
:
during the manoeuvre, and represent the maximum torque reached by
I)
motor 1 (35) and motor 2 (40).
These values allow the torque setting to be corrected.
If the maximum torque value reached during the manoeuvre gets sensibly