OPERATING AND MAINTENANCE MANUAL
SOLAR PUMPING GRUOP SERIE TH
NOTES:
ENG
•
The battery charge indicators only come on when the pump stops working and the speed regula-
tor is at minimum
•
If the "LOW POWER" indicator flashes, it means that the battery is overcharged.
3. BATTERY SELECTION (RECOMMENDED)
PUMP POWER
80 W
120 W
210 W
500 W
INSTRUCTIONS FOR THE WATER LEVEL PROBE
The water level probe system includes a tank level probe and a well level probe.
1. Tank level probe
The tank water level probe is used to check the water level in the tank to prevent water from exceeding
the capacity of the tank and spilling out. When the water level in the tank exceeds that of the probe, the
system will automatically stop pumping water. If the water level falls below the level of the probe, the
system will start up again.
2. Well level probe
The water level probe in the well is used to detect the level of water in the well, so as to prevent the
pump from running dry. When the water level in the well is below the well level probe, the system will
automatically stop pumping water. If the water level in the well rises above the probe again, the system
will start pumping again.
PUMP VOLTAGE
12 V
120 AH / 12 V / 1
24 V
120 AH / 12 V / 2
36 V
120 AH / 12 V / 3
48 V
120 AH / 12 V / 4
VALVE REGULATED MAINTENANCE FREE BATTERY
(CAPACITY / VOLTAGE / QUANTITY)
20
BATTERY CONNECTION
SERIES CONNECTION