Installing the unit
Deciding on where to install the outdoor unit
Decide the installation location regarding the following condition and obtain the user's approval.
The outdoor unit must not be placed on its side or upside down, as the compressor lubrication oil will run into the cooling
circuit and seriously damage the unit.
Choose a location that is dry and sunny, but not exposed to direct sunlight or strong winds.
Do not block any passageways or thoroughfares.
Choose a location where the noise of the Air to Water Heat Pump when running and the discharged air do not disturb
any neighbours.
Choose a position that enables the pipes and cables to be easily connected to the other hydrauric system.
Install the outdoor unit on a flat, stable surface that can support its weight and does not generate any unnecessary noise
and vibration.
Position the outdoor unit so that the air flow directly stream towards the open area.
Place the outdoor unit where there are no plants and animals because they may cause malfunction of outdoor unit.
Maintain sufficient clearance around the outdoor unit, especially from a radio, computer, stereo system, etc.
When installing the outdoor unit near seashore, make sure it is not directly exposed to sea breeze. If you can not find an
adequate place without direct sea breeze, make sure to apply anti-corrosion coating on the heat exchanger.
Install the outdoor unit in a place (such as near buildings etc.) where it can be prevented from sea breeze which can
damage the outdoor unit.
Sea breeze
Sea
If you cannot avoid installing the outdoor unit by the seashore, construct a protection wall around to block the sea
breeze.
Protection wall
Sea breeze
Sea
Install the outdoor unit in a place where water can drain smoothly.
❋ If you cannot find a place satisfying above conditions, please contact manufacturer. Make sure to clean the sea water
and the dust on the outdoor unit heat exchanger and spread corrosion inhibitor on heat exchanger.(At least one time
per one year.)
Depending on the condition of power supply, unstable power or voltage may cause malfunction of the parts or
control system. (At the ship or places using power supply from electric generator, etc).
CAUTION
14
Outdoor
unit
Outdoor
unit
Sea breeze
Sea
Protection wall should be constructed with a solid material such
as concrete to block the sea breeze and the height and the width
of the wall should be 1.5 times larger than the size of the outdoor
unit. Also, secure over 700mm between the protection wall and
the outdoor unit for exhausted air to ventilate.