5 OPERATION
1.
Open the side cover.
2.
Remove the feed roll retaining screw by turning it in a counter-clockwise direction.
3.
Change the feed roll.
4.
Tighten the feed roll retaining screw by turning it to clockwise position.
5.
Close the side cover.
NOTE!
The visual wire stamp designates the wire diameter groove in use.
5.7

Shielding gas

The choice of suitable shielding gas depends on the material. Typically mild steel is welded
with mixed gas (Ar + CO
with mixed gas (Ar + CO
argon gas (Ar). In the sMIG mode (see section "sMIG mode" in the CONTROL PANEL
chapter) the optimal welding arc with the gas you use will be automatically set.
0463 479 001
) or 100% carbon dioxide (CO
2
) or Trimix (He + Ar + CO
2
- 24 -
). Stainless Steel can be welded
2
). Aluminum and silicon bronze use pure
2
© ESAB AB 2017