Setting Of Position; Auxiliary Side Control; Anal Cleaning With Auxiliary Side Control; Drying With Auxiliary Side Control - Roca IN-WASH INSPIRA A803094001 Manual De Instrucciones

Ocultar thumbs Ver también para IN-WASH INSPIRA A803094001:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

3.2.3 SETTING OF POSITION

The nozzle can be adjusted in 5 positions. By
default it starts in a middle position allowing the
user to advance two positions and to move bac-
kwards two positions.

3.3 AUXILIARY SIDE CONTROL

The auxiliary side control can be used to monitor the main product functions: Anal cleaning and
dryer.
This auxiliary side control allows the use with medium settings.
These settings may not be customised:
• Medium temperature
• Medium pressure
• Middle position
The functions may only be activated when the lid is open and the device detects a user.

3.3.1 ANAL CLEANING WITH AUXILIARY SIDE CONTROL

The position of the nozzle is established beforehand; so is the water temperature.
With the function activated, by pressing the same button again the oscillating function is activated. If it is pressed again, it returns to the
normal mode (not oscillating).
To stop this function, press the Stop button on the auxiliary side control or on the remote control.
The cleaning stops after 2 minutes if no other button is pressed.
If the drying button is pressed while the anal cleaning is taking place, the cleaning stops and the drying is activated.

3.3.2 DRYING WITH AUXILIARY SIDE CONTROL

The drying function is established beforehand with a medium temperature.
To stop this function press the Stop button on the remote control or the auxiliary side unit. The drying stops after 3 minutes if no other button
is pressed.

3.3.3 STOP WITH THE AUXILIARY SIDE PANEL

It stops any activated function.

3.3.4 AUXILIARY SIDE PANEL FLUSHING

In case of power supply failure, or in case that the remote control runs out of batteries, it is
possible to make a full flush of the deposit, using the button on the auxiliary side panel.

3.4 CHANGE IN THE PRE-SET SETTINGS

3.4.1 CUSTOMISATION OF THE CLEANING AND DRYING SETTINGS

The In-Wash allows you to change the pre-set Temperature, Pressure and Position settings, which
are controlled by the remote control
By default, these baseline values are:
• Medium temperature: 36º perineal and anal.
• Medium pressure: 0.55 L/min in perineal, 0.75 L/min in anal.
• Position- 3 Perineal, 3 Anal.
To set a different value to the pre-set one, with the activated function, adjust each of the temperature,
pressure or position parameters to the desired level and press the + and - buttons simultaneously on
the remote control for 3 seconds.
Each temperature, pressure or position parameter needs to be set individually.
When the setting has been carried out, the In-Wash emits a beep and the lights in the remote control blink.
Therefore, if you wish to change the 3 settings of the anal cleaning, by instance, they should be pres-
sed successively with the activated function
Should you need to connect the remote control again these stored values would be lost.
To return to the pre-set standard values, see section 3.5.
FULL
FLUSH
3 s.
x2
21
Tabla de contenido
loading

Este manual también es adecuado para:

In-wash inspira a803095001In-wash inspira a803095000

Tabla de contenido