6.3. Finding and Troubleshooting Problems

Problem
Pump does not work

6.4. Notes on Personal Protective Gear

Wear appropriate protective gear (e.g. safety glasses, gloves, apron etc.) when handling
solvents.

7. Inspection / Maintenance_____________________________

7.1. Inspection

An experienced trained technician should inspect the unit at least every 12 months.
The examination of the Parts Cleaning Devices as stationary or moveable electrical devices,
has to be effected by the operator.

7.2. Maintenance

Depending on the type of application, the degree of contamination and duration of use, the
cleaning liquid must be exchanged by means of changing the drum. The unit must be
disconnected from the power supply before the drum is changed. Clean the unit regularly using
a cloth and/or cleaning solution. Original replacement parts must be ordered from the producer,
otherwise the warranty will be void.

8. Spare Parts and Accessories_________________________

The spare parts and accessories list for Parts Cleaner Type M / MD:
Article-No.
2222013
2222056
2222064
2221000
2222060
2222008
2222009
2222011
2222022
2221012
2222035
2222004
2222066
accessory
2222012
accessory
9700014
accessory
Operating Instructions Parts Cleaner Type M/MD (02/2010/EN)
Cause
No power
Pump is defective
Article-Name
Self priming pump with 2" thread
Self priming pump Type M complete with foot switch and 2" thread
Self priming pump Type M complete with foot switch (pneumatic)
Support grate (perforated sheet)
Support grate (lamellar grate)
Cleaning brush, fine – 50 mm bristles
Cleaning brush, coarse – 50 mm bristles
Cleaning brush, long bristles – 80 mm
Safety foot switch, with cover
Return hose
Thread plug 2"
Brush hose, 1,5 m
Splashback protector for Type M, height 470 mm
Special parts cleaning gloves (solvent-resistant)
Operating Instructions for Parts Cleaners
Solution
Check whether unit is plugged in
Replace pump