3. Function_______________________________________________

3.1. How the Machine Works

The self-priming pump transports the cleaning liquid throuh a hose to the hollow-cored cleaning
brush. The workpiece is placed onto the support grate and brushed off with cleaning liquid.
The dirty solvent drains from the support grate via basin and drain connection back into the
drum. By a process of chemical separation, the dirt and grease particles will sink to the bottom
of the drum. Once the cleaning effectiveness of the Special Cleaner is reduced, the solvent
drum needs to be replaced.
200-litre-drum with
Special Cleaner
(not included with unit)
power supply (230V) or
compressed air supply
(not visible)
Type MD (= Type M with cover)

3.2. Safety Information

see Section 6
Operating Instructions Parts Cleaner Type M/MD (02/2010/EN)
brush hose with
cleaning brush
Catch Basin Type WM
(available as accessory)
basin
support grate
self-priming pump
safety foot
switch