3M PRO-PROTECT Manual Del Usuario página 26

Idiomas disponibles

Idiomas disponibles

NOISE REDUCTION RATING (NRR)
PRO-PROTECT HEARING PROTECTION
25
The EPA references to Federal relate to US Federal laws.
ATTENUATION DATA | 3M PRO-PROTECT WITH STANDARD SEALING RINGS
TEST FREQUENCIES (HZ)
Mean Attenuation (dB)
Standard Deviation
The level of noise entering a person's ear when a hearing protector is worn as directed is closely approximated
by the difference between the A-weighted environmental noise level and the NRR.
EXAMPLE
1. The environmental noise level as measured at the ear is 92 decibels dB(A).
2. The NRR is 25 dB(A).
3. The level of noise entering the ear is approximately 67 dB(A).
26 English
Model 90545
125
250
500
1000 2000 3150 4000 6300 8000 NRR CSA Class
18.4
22.6
30.6
38.4
2.9
2.2
3.0
2.6
32
37.8
38.8
38.9
2.9
3.9
4.2
3.4
ANSI S3.19-1974
38.3
25
B
2.6
loading

Este manual también es adecuado para:

Pro-comms70009127427