Disconnect power before working on pump, motor, pressure switch, or wiring.
Single Phase
230 Volt to 115 Volt Conversion.
230 V
A
A
L 2
L 2
L 1
L 1
Clamp the power cable to prevent
strain on the terminals.
Connect the green (or bare copper)
ground wire to the grounding screw.
Figure 5 – Motor wiring connection, Plug-in.
ELECTRICAL
Ground motor before connecting to electrical
power supply.
Failure to ground motor can cause severe or
fatal electrical shock hazard.
Explosion hazard. Do not ground to a gas
supply line.
To avoid dangerous or fatal electrical shock,
turn OFF power to motor before working on
electrical connections.
Supply voltage must be within ± 10% of
nameplate voltage. Incorrect voltage can
cause fire or serious damage to motor and voids
warranty. If in doubt consult a licensed electrician.
Use wire size specified in Wiring Chart (Table II,
Page 6). If possible, connect pump to a separate
branch circuit with no other appliances on it.
Wire motor according to diagram on motor
nameplate. If nameplate diagram differs from
diagrams above, follow nameplate diagram.

WIRING CONNECTIONS

1. Install, ground, wire and maintain this pump in
compliance with the National Electrical Code (NEC)
or the Canadian Electrical Code (CEC) and with all
local codes and ordinances that apply. Consult your
local building inspector for local information.
Move plug to change voltage.
Ground
Screw
115 V
A
A
Power Supply
Wires
230 Volt to 115 Volt Conversion. Move plug to change voltage.
1.
Pull plug
straight
out from
terminal
board;
L 2
L 2
1.
L 1
L 1
Connect the green (or bare copper) ground
wire to the green ground screw.
Figure 6 – Motor wiring connection, Plug-in.
2. Make sure that the voltage, frequency and phase
(single phase or three phase) of the power supply
agree with that stamped on the motor nameplate. If
in doubt, check with the power company.
3. Some models are equipped with three phase
motors. Three phase motors require magnetic
starters and can run in either direction, depending
on how they are connected to the power supply.
NOTICE: Dual voltage motors without cords are factory
wired for 230 volts. If necessary, reconnect the motor for
115 volts, as shown. All cord connected motors are
wired for 115 volts (See Page 6). Do not alter the wiring
in single voltage motors.
Install, ground, wire, and maintain your pump in
comliance with the National Electrical Code (NEC) or
the Canadian Electrical Code (CEC), as applicable,
and with all local codes and ordinances that apply.
Consult your local building inspector for code
information.
NOTICE: Clamp the power cable to prevent strain on
the terminal screws.
NOTICE: Your Motor Terminal Board (under the
motor end cover) looks like one of those shown
above. Do not change motor wiring if line voltage
is 230 volts. Connect power supply as shown for
your supply voltage.
5
Single Phase
2.
Plug in again
with arrow
on plug
pointing to
'115 Volts'.
2.
A
L1
Clamp the power cable to prevent
strain on the terminals.
Ground
Screw
A
L1
3914 0301