Set working pressure and flow rate
Appliance setting
Turning the quantity regulation valve in clock-wise direction
will result in higher working pressure and larger volume.
Turning the quantity regulation valve in an anti-clockwise di-
rection will result in lower workign pressure and smaller quan-
tities.
Settings at the Easy press gun (optional)
Turning the water quantity regulator to the right gives more
water flow and higher working pressure.
Turning the water quantity regulator to the left gives lesser
water flow and lower working pressure.
Operating with cold water
Open the water supply.
Symbol "Engine on"
Pull the lever of the hand-spray gun and set the appliance
switch (A) to "1" (engine on).
The indicator lamp for operational readiness (F) shows that
the appliance is in stand-by mode and ready to be operated.
R
Operating with hot water
DANGER
Scalding danger!
ATTENTION
Hot water operations without fuel will cause damage to the fuel
pump. Ensure adequate fuel supply before starting hot water op-
erations.
If required, the burner can also be turned on subsequently.
Symbol "Burner on"
Turn the appliance switch (A) to "Burner on".
Set the desired water temperature on the thermostat (B).
Maximum temperature is 98 °C.
– The appliance will switch off if the lever of the hand-spray gun
is released during operations.
– The appliance will automatically start again when you open
the gun again within the stand-by period (2 ... 8 minutes).
– If the stand-by period is exceeded, the safety time mecha-
nism switches off the pump and the burner. The indicator
lamp Operations Stand-by (F) goes off.
– To restart the appliance, set the appliance switch to "0" and
then switch on the appliance again. If the appliance is operat-
ed using remote control, the appliance can be restarted by us-
ing the corresponding switch of the remote control device.
– Vehicle tyres are only cleaned using the flat spray nozzle
((25°) from a minimum spraying distance of 30 cm. The round
spray should never be used to clean tyres.
The following nozzles can be selected for all other tasks:
Dirt
Nozzle
strong
00060
medium
25060
light
40060
strong
00080
medium
25080
light
40080
Use the following nozzles if the pipe length is more than 20 m or
for more than 2 x 10 m high pressure hose NW8:
Dirt
Nozzle
strong
0075
medium
2575
light
4075
strong
0010
medium
2510
light
4010
5
-
EN
Operations stand-by
Selecting the nozzle
Spray an-
Part no.
Pressure
gle
6.415
[MPa]
HDS 9/16
0°
-649
25°
-647
40°
-648
HDS 12/14
0°
-150
25°
-152
40°
-153
Spray an-
Part no.
Pressure
gle
6.415
[MPa]
HDS 9/16
0°
-419
25°
-421
40°
-422
HDS 12/14
0°
-082
25°
-252
40°
-253
Recoil [N]
16
46
14
55
Recoil [N]
10
37
10
46
27