SICK WTL16 Instrucciones De Operación página 9

Ocultar thumbs Ver también para WTL16:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 88
6
COMMISSIONING
8
WTL16
Figure 5: Alignment
Sensing range
Check the application conditions: Adjust the sensing range and distance to the object
or background and the remission capability of the object according to the correspond‐
ing diagram
[see figure 6
between set sensing range and background (white 90%)). Remission: 6% = black 1,
18% = gray 2, 90% = white 3 (referring to standard white as per DIN 5033). We rec‐
ommend making the adjustments using an object with a low remission.
The minimum distance (= y) for background suppression can be determined from dia‐
gram
[figure
61] as follows:
Example: x = 200 mm, y = 15 mm. That is, the background (white, 90%) is suppressed
at a distance of > 15 mm from the sensor.
Minimum distance in mm (y) between the set sensing
range and background (white, 90%)
y
50
WTL16P-xxxxx1xx
18%/90%
2
45
1
40
6%/90%
35
3
30
Example:
90%/90%
Sensing range on black, 6%,
25
x = 200 mm, y = 15 mm
20
15
10
5
x
0
0
100
200
300
400
500
600
(3.94)
(7.87)
(11.81)
(15.75)
(19.69)
(23.62)
Distance in mm (inch)
Figure 6: Characteristic line 1, WTL16 Blue‐
tooth®-xxxxx1xx, red light
Sensing range on black, 6% remission
1
Sensing range on gray, 18% remission
2
Sensing range on white, 90% remission
3
WTS16
and
figure
7] (x = sensing range, y = minimum distance
1
50
white background (90%)
2
25
3
10
0
100
(3.94)
x
y
A
A = Detection distance (depending on object remission)
100
300
100
400
100
500
200
300
400
500
(7.87)
(11.81)
(15.75)
(19.69)
Distance in mm (inch)
Adjustment range
BluePilot:
Sensing range
indicator (blue LED)
Teach-Turn
adjustment
8022692.10DR | SICK
Subject to change without notice
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Wts16

Tabla de contenido