Removing the disposal bag
Illustration
Release and remove the suction head.
Pull the disposal bag up.
Pull the opening of the disposal bag out
toward the back over the suction sup-
port and seal it tightly.
Tightly seal the disposal bag with clo-
sure strips underneath the opening.
Remove the disposal bag.
Dispose of the used disposal bag ac-
cording to the local provisions.
Insert and lock the suction head.
– To vacuum wet dirt, always remove the
disposal bag.
General
– If wet dirt is vacuumed with the uphol-
stery or crevice nozzle (option) or if wa-
ter is sucked up from a container it is
recommended to deactivate the "auto-
matic filter dedusting" function.
– If the maximum liquid level is reached
the appliance will turn off automatically.
– In case of non-conductive liquids
(such as emulsion drilling fluids,
oils, and greases) the appliance is
not turned off when the container is
full. The filling level must be continu-
ously monitored and the container
must be emptied in time.
– After completion of the wet vacuuming:
Clean the flat pleated filter using the fil-
ter dedusting unit and allow the filter to
dry sufficiently. Clean the electrodes
using a brush. Clean the container with
a damp rag and dry it.
Clip connection
Illustration
The suction hose is equipped with a clip
system. All C-35/C-DN-35 accessories can
be connected.
18
Turning on the Appliance
Plug in the mains plug.
Switch on the appliance at the main
switch.
Adjust the suction output
Set the suction output (min - max) at the
rotary switch.
Regulating the suction power
Regulate the suction force on the suc-
tion force regulator (continuous).
Working with electrical power tools
DANGER
Risk of injury and damage! The socket out-
let is only for the connection of power tools
to the vacuum cleaner. Any other use of the
socket outlet is not permitted.
Connect the mains plug of the electric
power tool to the vacuum cleaner.
Switch on the appliance at the main
switch.
Indicator lamp is on; vacuum cleaner is in
the standby mode.
Note: The vacuum cleaner is turned on and
off automatically with the electric power tool.
Note: The vacuum cleaner starts automat-
ically within 0.5 seconds and continues to
run for 15 seconds after the power tool has
being switched off.
Note: Please refer to "Technical specifica-
tions" for the power connection specifica-
tions of the power tools.
Illustration
Adjust the universal adapter to the con-
nection of the electric power tool.
Illustration
Remove the elbow from the suction
hose.
Insert the universal adapter on the suc-
tion hose.
Illustration
Connect the universal adapter to the
electric tool, cut to the required diame-
ter if necessary.
– 4
EN
Operation