4.13 Faults and reporting
If there is a fault, an error code "Axx" is shown on the display.
In certain cases, the error code is accompanied by an icon:
FAULTS
flame failure A10
all faults except flame failure and water
pressure
water pressure
Reset function
To reset boiler operation in the event of a fault, press:
10
A
If the correct operating conditions have been restored, the boiler will start
up again automatically.
In the presence of a remote control, a maximum of 5 consecutive
unlocking attempts are available.
In this case, by pressing
the boiler restores the initial attempts.
b
If the attempts to reset the boiler do not work, contact the Techni-
cal Assistance Centre.
Fault A41
If the pressure value falls below the 0.3 bar safety value, the boiler shows
the fault code A41 for a transitory time of 10 min. If the fault still persists
after this time, fault code A40 will appear.
A
4
1 4
ERROR CODE
A10
A11
A20
A30
A40
A41
A42
A60
A70
A80
A90
A91
A58
A59
CFS
SFS
FIL
>3.0 bar
ICONS DISPLAYED
Res
> 2 sec
A
0
ERROR MESSAGE
Flame lockout
Condensate drain obstructed
Flue gas exhaust/air suction obstructed
Extraneous fl ame
Limit thermostat
Fan fault
Fill the system
Fill the system
Pressure transducer fault
DHW probe fault
Flow sensor fault
Flow sensor overtemperature
Flow/return sensor diff erential
Return probe fault
Return probe overtemperature
Return-fl ow sensor diff erential
Flue gas probe fault
Clean primary heat exchanger
Low power supply voltage
High power supply voltage
Call Service
Stop for Service
Low pressure - check system
High pressure - check system
With fault A40 on the boiler it is necessary to:
- open the filling tap (A) turning it counterclockwise
- access the Info menu ("5.3 INFO menu
the pressure value reaches 1-1.5 bar
- close the filling tap (A) making sure you hear the mechanical click.
Press
to restore operation. After filling, run a venting cycle. If the
pressure drop is very frequent, contact the Technical Assistance Centre.
Fault A60
Provide any stability of the domestic hot water temperature that, in any
event, is supplied at a temperature of around 50°C. The intervention of
the Technical Assistance Centre is required.
Fault A91
The boiler has a self-diagnosis system that signals the need to clean the
primary heat exchanger on the basis of the total number of hours in cer-
tain operating conditions (alarm code A91). Fault A91 occurs when the
counter exceeds the value of 2500 hours; this value can be checked in
the "5.3 INFO menu
", item I015 (visualization/100, example 2500h
= 25).
After cleaning (using the special kit supplied as an accessory), reset the
total hours counter by bringing parameter 312 = 1.
NOTE: The meter resetting procedure should be carried out after each
in-depth cleaning of the primary exchanger or if this latter is re-
placed.
4.14 Replacing the board
If the check and adjustment board is replaced, it may be necessary to
reprogram the configuration parameters. In this case, refer to the pa-
rameters table to see the board default values, the factory set values,
and the personalised values. The parameters that must be checked and
reset if necessary after replacing the board are: 301 - 302 (SERVICE) -
306 - 307 - 308 - 309 - 310.
DESCRIPTION OF TYPE OF ALARM
30
", item I018) to check that
A
defi nitive
transitional
defi nitive
defi nitive
defi nitive
transitional
defi nitive
transitional
transitional
defi nitive
defi nitive
transitional
defi nitive
defi nitive
transitional
transitional
transitional
transitional
signal
defi nitive
signal
signal