iNSTallaTiON
Service information
Installing the appliance
1
1 Grommets
2 Flat gasket
3 Strainer with sealed edge
f Mark out the 2 holes for drilling with reference to the appli-
f
ance back panel.
f Fit the grommets in the appliance back panel from the front.
f
f Drill the holes and secure the appliance using suitable fixing
f
materials (screws and rawl plugs are not part of the standard
delivery): Countersunk screw, Ø 4.5 mm, max. diameter of
screw-head 9 mm.
Note
f Install the appliance flush to the wall. If necessary,
f
additionally secure the appliance at the 2 lower at-
tachment points.
f Remove the transport protection plugs from the water con-
f
nection pipes.
f Secure the DHW connection pipe with a flat gasket and the
f
cold water inlet line with the sealed-edge strainer (from the
accessories) to the twin connectors.
12.6 Operation with preheated water
You can limit the maximum inlet temperature by installing a cen-
tral thermostatic valve.
www.stiebel-eltron.com
2
3
13. Service information
Connection overview / component overview
1
2
1 Flow meter
2 High limit safety cut-out, automatic reset
3 Pin strip for connected load
4 Diagnostic traffic lights
3
4
DCE-C Trend |
11