a
Function selections
1 ON -
Automatic closing - The automatic closing timer is automatically activated at the end of the opening cycle. The preset, adjustable automatic closing
time is automatically interrupted by the activation of any safety system, and is deactivated after a total stop command or in case of power failure;
2 ON -
Radio function command and/or "open-stop-close-stop" button (with radio-frequency card inserted).
2 OFF - Radio function command and/or "open-close-inversion" button (with radio-frequency card inserted).
3 ON -
Radio function command "only open" (with radio-frequency card inserted).
4 ON -
"Maintained Action" operations - Operation of the gate by keeping the pushbutton pressed for opening on 2-3, button for closing on 2-4 (excluding
the radio transmitter operations).
5 ON -
"Pre-fl ashing during opening and closing" - After an opening or closing command, the fl ashing lamp connected to W-E1 fl ashes for 5 seconds before
beginning the manoeuvre.
6 ON -
Obstacle detection - With the motor not running (gate closed, open or after a total stop command), this hinders any movement if the safety devices
(e.g. photoelectric cells) detect an obstacle.
7 OFF
Re-opening during closure - If the photoelectric cells identify an obstacle while the bar is closing, they will reverse the direction of movement until
the gate is completely open; insert safety device on the clamp (2-C1); if not used, select the dip in ON.
8 OFF - Partial stop - The gate stops if in motion with resulting order of automatic closing, insert safety device on the clamp (2-C3); if not used, set the dip
to ON.
9 OFF - Total stop - This function stops the gate, with the resulting exclusion of an automatic closing cycle; to resume movement, the pushbuttons or tran-
smitters must be used. Insert the safety device on (1-2); if not used, set the dip to ON.
10 OFF- If unused, leave the dip-switch in the "OFF" position
b
Adjustments
Trimmer A.C.T. = Automatic closing time. Adjusts the wait time of the gate in the open position, also known as "pause time"; at the end of this
time, a closing movement is automatically activated. The "pause time" can be adjusted from 1 second to 120 seconds.
Trimmer PAR.OP. = Partial opening. Adjusts the opening time of the gate. By pressing the partial opening button on 2-3P, the gate will open for
a set time between 2 and 15 seconds.
The automatic closing time will change in the following manner with this function:
- dip-switch 1 to ON «activated automatic closure» the closing time is set by adjusting the A.C.T. trimmer after partial opening;
- dip-switch 1 to OFF «deactivated automatic closure», with A.C.T. trimmer set to the minimum setting, automatic closure counting does not start
after partial opening; con trimmer del A.C.T. set to the maximum setting, the closing time is fi xed at 8 seconds after partial opening.
8
The data and information provided in this manual are to be considered susceptible to change at any time without warning, by CAME cancelli automatici s.p.a.