Installing The Ventilation System - Dometic 8 Serie Instrucciones De Montaje

Nevera con extractor
Ocultar thumbs Ver también para 8 Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Installation
1
2
Ventilation grille LS 100 or LS 200
1
2
Ventilation grille LS 200
The gas burner must be located above the
edge (1, Fig. 17).
1
Should this arrangement prove impossible,
a ventilation aperture must be introduced
by the manufacturer of the vehicle into the
recess floor in order to avoid the accumula-
tion of unburnt gas on the floor.
The ventilation grilles must have an open
cross-section of at least 250cm². This is
achieved by using the Dometic LS100/LS 200
absorber ventilation and air extraction system
which has been tested and approved for this
purpose.
1
2
Fig. 16
Fig. 17

4.3 Installing the ventilation system

The LS 100 upper vent system kit consists of
the mounting frame (RS 1640), the air grille
including flue gas duct (AS 1620) and the win-
ter cover (WA120). The LS 200 lower vent
system kit consists of the mounting frame (RS
1650), the air grille (AS1 630, but without flue
gas duct) and the winter cover (WA130).
LS 100
4
LS 200
Correct mounting of the lower ventilation gril-
le facilitates access to the connections and
functional parts during maintenance.
CAUTION!
An installation other than described will
reduce the cooling capacity and jeopardi-
se the manufacturer's warranty/product
liability.
14
1
2
3
Fig. 18
Fig. 19

Capítulos

Tabla de contenido
loading

Tabla de contenido