ECOFOREST Vigo Manual De Instalación Y Mantenimiento página 45

Ocultar thumbs Ver también para Vigo:
Idiomas disponibles
  • ES

Idiomas disponibles

CONVECTOR
MOTOR
DISCONNECTED.
EXTRACTION
MOTOR
DISCONNECTED.
ENDLESS
MOTOR
DISCONNECTED.
ELECTRODE
(START-UP
RESISTANCE)
DISCONNECTED.
CONVECTOR MOTOR IN
SHORT-CIRCUIT.
SHORT-CIRCUIT OF THE
EXTRACTION MOTOR.
ENDLESS MOTOR SHORT-
CIRCUIT.
necessary for combustion to happen.
 The C.P.U. does not detect the Convector.
 The C.P.U. does not detect the Extractor.
 The C.P.U. does not detect the reduction
motor of the endless motor.
 The C.P.U. does not detect the start-up
Electrode (start-up resistance).
 The Unicontril detects that the convector or
the
output
voltage
corresponding to the convector is in short-
circuit.
 The C.P.U. detects that the Extractor of
tension outlet of the C.P.U. corresponding to
the extractor is in short-circuit.
 The C.P.U. detects that the reduction motor
or tension output of the C.P.U. corresponding
to the reduction motor is in short-circuit.
 Stove
maintenance.
 Air entrance pipe stacked. Clean air Entrance
pipe.
 Air reading pipe (transparent silicone pipe
linking the C.P.U. to the air inlet pipe),
disconnected or cut. Connect or replace.
 Extractor does not turn.
 Failure in depression reading system of the
C.P.U., check depression air level, cf. Menu 3,
chapter 1 (S.A.T.)
 If the stove is new, this might be due to
electric power problems.
 Check the convection motor is connected to
power through menu 3 section 0.
 Check the grey cable going out from the
C.P.U. Connect it if necessary.
 If the stove is new, this might be due to
electric power problems.
 Check is power is being supplied to the
exhaust motor through menu 3 section 1.
 Check the red cable going out from the C.P.U.
Connect it if necessary.
 If the stove is new, this may be due to
electrical problems.
 Check if the endless motor is connected to
power, see menu 3 section 2.
 If power does not reach the endless motor,
check-with the stove disconnected- if the
safety thermostat is activated. Reactivate if
necessary.
 If the stove is new, this might be caused by
electrical problems.
 Make sure power reaches the start-up
resistance, see menu 3 section 3.
 Check the black cable going out from the
C.P.U. Connect it if necessary.
 If the stove is new, this might be caused by
electrical problems.
 Check with a multimeter if the motor is
of
the
C.P.U.
clamped to earth or the winding is in short-
circuit. Make sure power reaches the
convection motor, see menu 3 section 0.
 Check the grey cable going out from the
C.P.U. Connect it if necessary.
 If the stove is new, this might be caused by
electrical problems.
 Check with a multimeter if the motor is
clamped to earth or the winding is in short-
circuit. Make sure power reaches the
convection motor, see menu 3 section 1.
 Check the red cable going out from the C.P.U.
Connect it if necessary.
 Make sure power reaches the endless motor,
see menu 3 section 2.
 Check with a multimeter if the motor is
clamped to earth or the winding is in short-
circuits.
 Check the brown cable going out from the
C.P.U. Connect it if necessary.
44
full
of
ash
inside.
Carry
out