ECOFOREST Vigo Manual De Instalación Y Mantenimiento página 44

Ocultar thumbs Ver también para Vigo:
Idiomas disponibles
  • ES

Idiomas disponibles

THE GAS OUTLET EXTRACTOR DOES NOT WORK OR DOES NOT WORK CORRECTLY:
6.18. Make sure the motor rotates properly by rotating it with your hand (the stove should be disconnected to do
so).
6.19. Check that power reaches the motor, by turning the stove on.
6.20. Also check the exhaust connection strip and the C.P.U.
THE CONVECTION FAN DOES NOT ROTATE:
6.21. Make sure that the turbine is not stalled by unplugging the stove. Then access to the right side and rotate it
with your hand to ensure that it rotates perfectly.
THE STOVE TURNS OFF:
6.22. There might be no pellets in the stove.
6.23. A forgotten set programme might have stopped the stove. Check the programmation of the stove at points
1-2 or 1-3. Also see chrono settings at point 1-4a show a NO.
6.24. A bad quality of pellets, humidity can be causes of unexpected stops.
6.25. If the stove turns off and there are half burnt pellets in the burn pot, this might be due to a lack of cleaning.
Revise chapter related to cleaning and maintenance.
6.26. Internal dirt or ongoing use without cleaning.
6.27. If the stove is off and there are no pellets in the burn pot, check the reducer motor, convection motor and
extractor.
MESSAGE
IF NOTHING STARTS-UP.
AT START-UP, THE STOVE
PRODUCES A BIP BUT
DISPLAY DOES NOT START.
EVERYTHING
STARTS-UP
BUT KEYBOARD DOES NOT
EXECUTE.
AFTER SOME TIME OF
OPERATION, IT INDICATES
CHANGES IN AIR LEVEL
AND PELLETS STACK IN
THE BASKET.
DOOR OPEN OR ERROR IN
DEPRESSION.
ALSO CONSIDER THE FOLLOWING...
DESCRIPTION
 No power supply.
 Power cable badly connected or cut.
 Fuse C.P.U. burned.
 EMI power filter damaged.
 Check connection of keyboard's belt.
 Flat belt damaged.
 Keyboard panel damaged.
 Control unit damaged.
 Check connection of keyboard's belt.
 Flat belt damaged.
 Keyboard panel damaged.
 Control unit damaged.
 The stove needs air for combustion.
 Check the Lumber of hours of operation since
last maintenance (Menu 2-5).
 Check pellets quality.
 As indicated, the fireplace door is open or
there is a failure in the air Redding system
 Make sure there is power.
 Replace cable.
 Replace fuse. If the fuse is burnt, this is the
reason why the hardware is cancelled and
there is a short-circuit with a ~230/240V -
50Hz item. Check any possible short-circuits
with a multimeter.
 Inform your distributor so that he replaces it.
 If it is doubled or deformed, replace it.
 Replace it.
 Replace it.
 Advise your distributor to repair or replace it.
 If it is doubled or deformed, replace it.
 Replace it.
 Replace it.
 Advise your distributor to repair or replace it.
 Make sure fireplace door and ash box are well
closed.
 Carry out maintenance.
 Replace the bag of pellets by another bag;
make sure it is stored in a dry place.
 Fireplace door open. Close the door.
 Gas outlet pipe stacked. Clean gas outlet.
43
SOLUTIONS

Hide quick links:

Capítulos

loading

Este manual también es adecuado para:

CíesParísAtenas